Simultaneous determination of bromide, bromate and nitrite in low μg 1-1 levels by ion chromatography without sample pretreatment

被引:98
作者
Salhi, E [1 ]
von Gunten, U [1 ]
机构
[1] Swiss Fed Inst Environm Sci & Technol, EAWAG, CH-8600 Dubendorf, Switzerland
关键词
ion chromatography; postcolumn reaction; bromide; bromate; nitrite; drinking water; ozonation;
D O I
10.1016/S0043-1354(99)00053-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new ipn chromatographic method has been developed for the simultaneous analysis of the major matrix anions (chloride, nitrate, phosphate, sulfate, etc.), lower concentrated bromide, oxyhalides (iodate, chlorite, bromate) and nitrite in fresh waters and sea water. The method is based on an anion exchange chromatographic separation followed by a sequential analysis through conductivity and subsequent postcolumn reaction with UV detection: Whereas the matrix anions are quantified by conductivity, the oxyhalides and nitrite are measured by the oxidation product I; which they generate from iodide in the postcolumn reaction. The detection limits as determined for bromide, bromate and nitrite are 3, 0.1 and 0.5 mu g l(-1), respectively. (C) 1999 Elsevier Science Ltd. Ail rights reserved.
引用
收藏
页码:3239 / 3244
页数:6
相关论文
共 17 条
[1]   Determination of iodide and iodate by ion chromatography with postcolumn reaction and UV/visible detection [J].
Bichsel, Y ;
von Gunten, U .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :34-38
[2]   Determination of bromate in drinking waters by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Pfaff, JD ;
Brockhoff, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :261-267
[3]   SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS [J].
GINE, MF ;
BERGAMIN, H ;
ZAGATTO, EAG ;
REIS, BF .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :191-197
[4]  
GODET JL, 1998, P IOA REG C POIT FRA
[5]   High selective determination of bromate in ozonized water by using ion chromatography with postcolumn derivatization equipped with reagent preparation device [J].
Inoue, Y ;
Sakai, T ;
Kumagai, H ;
Hanaoka, Y .
ANALYTICA CHIMICA ACTA, 1997, 346 (03) :299-305
[6]  
KOLTHOFF IM, 1957, VOLUMETRIC ANAL, V3
[7]   BROMATE ION ANALYSIS BY ION CHROMATOGRAPHY [J].
KOUDJONOU, BK ;
MULLER, MC ;
COSTENTIN, E ;
RACAUD, P ;
VANDERJAGT, H ;
VILARO, JS ;
HUTCHISON, J .
OZONE-SCIENCE & ENGINEERING, 1995, 17 (05) :561-573
[8]   A survey of bromate ion in European drinking water [J].
Legube, B .
OZONE-SCIENCE & ENGINEERING, 1996, 18 (04) :325-348
[9]   Ultra-trace determination of bromate in drinking waters by means of microbore column ion chromatography and on-line coupling with inductively coupled plasma mass spectrometry [J].
Nowak, M ;
Seubert, A .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :193-204
[10]   The catalytic effect of Mo-V on the oxidation of iodide by chlorate [J].
Villata, LS ;
Martire, DO ;
Capparelli, AL .
JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 1997, 123 (2-3) :85-90