Carotid artery stenosis: reproducibility of automated 3D CT angiography analysis method

被引:49
作者
Zhang, ZS
Berg, MH
Ikonen, AEJ
Vanninen, RL
Manninen, HI
机构
[1] Kuopio Univ Hosp, Dept Clin Radiol, SF-70210 Kuopio, Finland
[2] Cent S Univ, Xiangya Hosp 2, Dept Radiol, Changsha 410011, Peoples R China
关键词
CT angiography; carotid stenosis; spiral CT;
D O I
10.1007/s00330-003-2130-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the reproducibility and anatomical accuracy of automated 3D CT angiography analysis software in the evaluation of carotid artery stenosis with reference to rotational DSA (rDSA). Seventy-two vessels in 36 patients with symptomatic carotid stenosis were evaluated by 3D CT angiography and conventional DSA (cDSA). Thirty-one patients also underwent rotational 3D DSA (rDSA). Multislice CT was performed with bolus tracking and slice thickness of 1.5 mm (1-mm collimation, table feed 5 mm/s) and reconstruction interval of 1.0 mm. Two observers independently performed the stenosis measurements on 3D CTA and on MPR rDSA according to the NASCET criteria. The first measurements on CTA utilized an analysis program with automatic stenosis recognition and quantitation. In the subsequent measurements, manual corrections were applied when necessary. Interfering factors for stenosis quantitation, such as calcifications, ulcerations, and adjacent vessels, were registered. Intraobserver and interobserver correlation for CTA were 0.89 and 0.90, respectively. (p<0.001). The interobserver correlation between two observers for MPR rDSA was 0.90 (p<0.001). The intertechnique correlation between CTA and rDSA was 0.69 (p<0.001) using automated measurements but increased to 0.81 (p<0.001) with the manually corrected measurements. Automated stenosis recognition achieved a markedly poorer correlation with MPR rDSA in carotids with interfering factors than those in cases where there were no such factors. Automated 3D CT angiography analysis methods are highly reproducible. Manually corrected measurements facilitated avoidance of the interfering factors, such as ulcerations, calcifications, and adjacent vessels, and thus increased anatomical accuracy of arterial delineation by automated CT angiography with reference to MPR rDSA.
引用
收藏
页码:665 / 672
页数:8
相关论文
共 28 条
[1]  
Alvarez-Linera J, 2003, AM J NEURORADIOL, V24, P1012
[2]   CT angiography for the detection and characterization of carotid artery bifurcation disease [J].
Anderson, GB ;
Ashforth, R ;
Steinke, DE ;
Ferdinandy, R ;
Findlay, JM .
STROKE, 2000, 31 (09) :2168-2174
[3]   Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis [J].
Barnett, HJM ;
Taylor, W ;
Eliasziw, M ;
Fox, AJ ;
Ferguson, GG ;
Haynes, RB ;
Rankin, RN ;
Clagett, GP ;
Hachinski, VC ;
Sackett, DL ;
Thorpe, KE ;
Meldrum, HE ;
Spence, JD .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (20) :1415-1425
[4]   CT angiography in the assessment of carotid artery atherosclerosis -: A comparative analysis with MR angiography with reference to contrast angiography and intravascular ultrasound [J].
Berg, MH ;
Manninen, HI ;
Räsänen, HT ;
Vanninen, RL ;
Jaakkola, PA .
ACTA RADIOLOGICA, 2002, 43 (02) :116-124
[5]  
CARVI Y, 2002, NEUROSURGERY, V50, P1283
[6]   Helical CT angiography in the preoperative evaluation of carotid artery stenosis - Discussion [J].
Reilly, LM ;
Cinat, M ;
Strandness, E ;
Moneta, G .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :297-300
[7]   CAROTID-ARTERY STENOSIS - A PROSPECTIVE COMPARISON OF CT ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY [J].
CUMMING, MJ ;
MORROW, IM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :517-523
[8]   Maximum internal carotid arterial stenosis:: Assessment with rotational angiography versus conventional intraarterial digital subtraction angiography [J].
Elgersma, OEH ;
Buijs, PC ;
Wüst, AFJ ;
van der Graaf, Y ;
Eikelboom, BC ;
Mali, WPTM .
RADIOLOGY, 1999, 213 (03) :777-783
[9]   Carotid stenting and endarterectomy - A clinical and cost comparison of revascularization strategies [J].
Gray, WA ;
White, HJ ;
Barrett, DM ;
Chandran, G ;
Turner, R ;
Reisman, M .
STROKE, 2002, 33 (04) :1063-1070
[10]   Maximum stenosis of extracranial internal carotid artery: Effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA [J].
Hirai, T ;
Korogi, Y ;
Ono, K ;
Murata, Y ;
Takahashi, M ;
Suginohara, K ;
Uemura, S .
RADIOLOGY, 2001, 221 (03) :802-809