Comparison of the Nonspecific Binding of DNA-Conjugated Gold Nanoparticles between Polymeric and Monomeric Self-Assembled Monolayers

被引:30
作者
Das, Jagotamoy [1 ,2 ]
Huh, Chan-Hwa [1 ,2 ]
Kwon, Kiyeon [1 ,2 ]
Park, Sangjin [3 ]
Jon, Sangyong [3 ]
Kim, Kyuwon [4 ]
Yang, Haesik [1 ,2 ]
机构
[1] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
[2] Pusan Natl Univ, Chem Inst Funct Mat, Pusan 609735, South Korea
[3] Gwangju Inst Sci & Technol, Dept Life Sci, Kwangju 500712, South Korea
[4] Univ Incheon, Dept Chem, Inchon 402749, South Korea
关键词
SURFACE-PLASMON RESONANCE; NANOCATALYST-BASED ASSAY; TIN OXIDE ELECTRODES; POLY(ETHYLENE GLYCOL); ELECTROCHEMICAL DNA; NUCLEIC-ACIDS; PROTEIN; OLIGONUCLEOTIDE; NANOSTRUCTURES; CONSTRUCTION;
D O I
10.1021/la802531d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The nonspecific binding of DNA-conjugated gold nanoparticles (AuNPs) to solid surfaces is more difficult to control than that of DNA molecules due to the more attractive interactions from the large number of DNA molecules per AuNP. This paper reports that the polymeric self-assembled monolayers (SAMs) formed on indium-tin oxide (ITO) electrodes significantly inhibit the nonspecific binding of DNA-conjugated AuNPs. The random copolymers used to prepare the polymeric SAMs consist of three functional parts: an ITO-reactive silane group, a DNA-blocking poly(ethylene glycol) (PEG) group, and an amine-reactive N-acryloxysuccinimide group. In order to compare the polymeric SAMs with various monomeric SAMs, the relative nonspecific binding of the DNA-conjugated AuNPs to the ITO electrodes modified with (3-aminopropyl)triethoxysilane (APTES), 3-aminopropylphosphonic acid, 3-phosphonopropionic acid, or 11-phosphonoundecanoic acid is examined by measuring the electrocatalytic anodic current of hydrazine caused by the nonspecifically absorbed AuNPs and by counting the AuNPs adsorbed onto modified ITO electrodes. Carboxylic-acid-terminated and amine-terminated monomeric SAMs cause high levels of nonspecific binding of DNA-conjugated AuNPs. The monomeric SAM modified with the carboxylic-acid-terminated poly(amidoamine) dendrimer shows low levels of nonspecific binding (2.0% nonspecific binding relative to APTES) due to the high surface density of the negative charge. The simply prepared polymeric SAM produces the lowest level of nonspecific binding (0.8% nonspecific binding relative to APTES), resulting from the combined effect of (i) DNA-blocking PEG and carboxylic acid groups and (ii) dense polymeric SAMs. Therefore, thin and dense polymeric SAMs may be effective in electrochemical detection and easy DNA immobilization along with low levels of nonspecific binding.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 52 条
[1]   Ultrathin functional star PEG coatings for DNA microarrays [J].
Ameringer, T ;
Hinz, M ;
Mourran, C ;
Seliger, H ;
Groll, J ;
Moeller, M .
BIOMACROMOLECULES, 2005, 6 (04) :1819-1823
[2]   Modification of indium tin oxide electrodes with nucleic acids: Detection of attomole quantities of immobilized DNA by electrocatalysis [J].
Armistead, PM ;
Thorp, HH .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3764-3770
[3]   Regenerable biosensor platform: A total internal reflection fluorescence cell with electrochemical control [J].
Asanov, AN ;
Wilson, WW ;
Odham, PB .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1156-1163
[4]   Amperometric immunosensing using an indium tin oxide electrode modified with multi-walled carbon nanotube and poly(ethylene glycol)-silane copolymer [J].
Aziz, Md. Abdul ;
Park, Sangjin ;
Jon, Sangyong ;
Yang, Haesik .
CHEMICAL COMMUNICATIONS, 2007, (25) :2610-2612
[5]   DNA microarrays with PAMAM dendritic linker systems -: art. no. e10 [J].
Benters, R ;
Niemeyer, CM ;
Drutschmann, D ;
Blohm, D ;
Wöhrle, D .
NUCLEIC ACIDS RESEARCH, 2002, 30 (02) :10
[6]  
Benters R, 2001, CHEMBIOCHEM, V2, P686, DOI 10.1002/1439-7633(20010903)2:9<686::AID-CBIC686>3.0.CO
[7]  
2-S
[8]   Electrochemical sensing of DNA using gold nanoparticles [J].
Castaneda, M. T. ;
Alegret, S. ;
Merkoci, A. .
ELECTROANALYSIS, 2007, 19 (7-8) :743-753
[9]   Gold and silica-coated gold nanoparticles as thermographic labels for DNA detection [J].
Cerruti, Marta G. ;
Sauthier, Marc ;
Leonard, Donovan ;
Liu, Dage ;
Duscher, Gerard ;
Feldheim, Daniel L. ;
Franzen, Stefan .
ANALYTICAL CHEMISTRY, 2006, 78 (10) :3282-3288
[10]   Immobilization of oligonucleotides on poly(ethylene glycol) brush-coated Si surfaces [J].
Cha, TW ;
Boiadjiev, V ;
Lozano, J ;
Yang, H ;
Zhu, XY .
ANALYTICAL BIOCHEMISTRY, 2002, 311 (01) :27-32