Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study

被引:29
作者
Frazier, OH [1 ]
Tuzun, E [1 ]
Cohn, WE [1 ]
Conger, JL [1 ]
Kadipasaoglu, KA [1 ]
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Cardiovasc Surg Res Labs, Houston, TX USA
关键词
D O I
10.1097/01.mat.0000196827.61241.07
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the midatrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100 +/- 10 mmHg (systemic) and 20 +/- 5 mmHg (pulmonary) and both left and right atrial pressures at 15 +/- 5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.
引用
收藏
页码:145 / 149
页数:5
相关论文
共 17 条
[1]  
AKUTSU T, 1958, T AM SOC ART INT ORG, V4, P230
[2]   Infection and thrombosis in total artificial heart technology: Past and future challenges - A historical review [J].
Conger, JL ;
Inman, RW ;
Tamez, D ;
Frazier, OH ;
Radovancevic, B .
ASAIO JOURNAL, 2000, 46 (06) :S22-S27
[3]   Total artificial heart bridge to transplantation: A 9-year experience with 62 patients [J].
Copeland, JG ;
Smith, RG ;
Arabia, FA ;
Nolan, PE ;
McClellan, D ;
Tsau, PH ;
Sethi, GK ;
Bose, RK ;
Banchy, ME ;
Covington, DL ;
Slepian, MJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (07) :823-831
[4]   Cardiac replacement with a total artificial heart as a bridge to transplantation [J].
Copeland, JG ;
Smith, RG ;
Arabia, FA ;
Nolan, PE ;
Sethi, GK ;
Tsau, PH ;
McClellan, D ;
Slepian, MJ ;
Foy, B ;
Long, J ;
Doty, D ;
Tector, A ;
Kormos, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (09) :859-867
[5]  
Crump K R, 1990, ASAIO Trans, V36, pM254
[6]   The 'Berlin Heart' assist device [J].
Drews, T ;
Loebe, M ;
Hennig, E ;
Kaufmann, F ;
Müller, J ;
Hetzer, R .
PERFUSION-UK, 2000, 15 (04) :387-396
[7]   SEPARATION OF THE NATURAL ATRIA IN EXPERIMENTAL IMPLANTATION OF TOTAL ARTIFICIAL-HEART [J].
FRAZIER, OH ;
PARNIS, SM ;
MCGEE, MG ;
FUQUA, JM .
ARTIFICIAL ORGANS, 1995, 19 (08) :864-866
[8]  
Frazier OH, 2004, TEX HEART I J, V31, P157
[9]   The total artificial heart: Where we stand [J].
Frazier, OH ;
Dowling, RD ;
Gray, LA ;
Shah, NA ;
Pool, T ;
Gregoric, I .
CARDIOLOGY, 2004, 101 (1-3) :117-121
[10]   1ST HUMAN USE OF THE HEMOPUMP, A CATHETER-MOUNTED VENTRICULAR ASSIST DEVICE [J].
FRAZIER, OH ;
WAMPLER, RK ;
DUNCAN, JM ;
DEAR, WE ;
MACRIS, MP ;
PARNIS, SM ;
FUQUA, JM .
ANNALS OF THORACIC SURGERY, 1990, 49 (02) :299-304