Adduct formation in quantitative bioanalysis: Effect of ionization conditions on paclitaxel

被引:83
作者
Mortier, KA [1 ]
Zhang, GF [1 ]
Van Peteghem, CH [1 ]
Lambert, WE [1 ]
机构
[1] State Univ Ghent, Toxicol Lab, B-9000 Ghent, Belgium
关键词
D O I
10.1016/j.jasms.2003.12.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative analysis of target compounds with liquid chromatography atmospheric pressure ionization mass spectrometry is sometimes hampered by adduct formation. In these situations, cationization with alkali metal ions instead of proton addition is often observed in the positive ion mode. This work studies the process of adduct formation and investigates potential strategies to control this phenomenon. Paclitaxel, a pharmaceutical chemotherapeutic agent, was used as a model compound. Electrospray (ESI), atmospheric pressure chemical ionization (APCI) and sonic spray ionization (SSI) are evaluated and compared. The work was performed on two different instruments, allowing the evaluation of different ionization behavior for different source design for electrospray, if any. Different mobile phase additives were compared, including acetic acid, formic acid, ammonium formate, and a range of primary amines. Continuous infusion was used for a fast screening, to detect optimal conditions. These were then further investigated in detail by LC-MS. The results indicate that electrospray is the more sensitive interface for this compound on the investigated apparatus. Unacceptable quantitative data were acquired without additives in the mobile phase. Generally, additives increased the reproducibility significantly. A response of mainly one ion was achieved with dodecylamine/acetic acid and acetic acid/sodium acetate. The data also point out the importance of evaluating adduct formation for compounds prone to this phenomenon during method development, especially in view of accurate quantitation. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:585 / 592
页数:8
相关论文
共 17 条
[1]   Measurement of paclitaxel in biological matrices: high-throughput liquid chromatographic-tandem mass spectrometric quantification of paclitaxel and metabolites in human and dog plasma [J].
Alexander, MS ;
Kiser, MM ;
Culley, T ;
Kern, JR ;
Dolan, JW ;
McChesney, JD ;
Zygmunt, J ;
Bannister, SJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :253-261
[2]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[3]  
2-S
[4]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[5]   Postcolumn introduction of an internal standard for quantitative LC-MS analysis [J].
Choi, BK ;
Gusev, AI ;
Hercules, DM .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :4107-4110
[6]   UTILITY OF ORGANIC-BASES FOR IMPROVED ELECTROSPRAY MASS-SPECTROMETRY OF OLIGONUCLEOTIDES [J].
GREIG, M ;
GRIFFEY, RH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (01) :97-102
[7]  
Jemal M, 1997, RAPID COMMUN MASS SP, V11, P1083, DOI 10.1002/(SICI)1097-0231(19970630)11:10<1083::AID-RCM937>3.3.CO
[8]  
2-6
[9]   Liquid chromatography-electrospray mass spectrometric studies of ginkgolides and bilobalide using simultaneous monitoring of proton, ammonium and sodium adducts [J].
Li, XF ;
Ma, MS ;
Scherban, K ;
Tam, YK .
ANALYST, 2002, 127 (05) :641-646
[10]   A study of the effect of pH, solvent system, cone potential and the addition of crown ethers on the formation of the monensin protonated parent ion in electrospray mass spectrometry [J].
Lopes, NP ;
Stark, CBW ;
Hong, H ;
Gates, PJ ;
Staunton, JZ .
ANALYST, 2001, 126 (10) :1630-1632