Validation of a new method of detecting peripheral artery disease by determination of ankle-brachial index using an automatic blood pressure device

被引:33
作者
Benchimol, A
Bernard, V
Pillois, X
Hong, NT
Benchimol, D
Bonnet, J
机构
[1] INSERM, U441, Pessac, France
[2] Hop Cardiol, Pessac, France
[3] Serv Med Inter Entreprise, Saintes, France
[4] Hop Tran Hung Dao, Hanoi, Vietnam
关键词
D O I
10.1177/000331970405500203
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Peripheral artery disease (PAD) is a predictor of total and cardiovascular mortality; its most valuable simple index is the ankle-brachial index (ABI). The present study was designed to assess whether a commercially available automatic device could be used to determine ABI in comparison with the classical Doppler method. The ABI was defined as the ratio of systolic blood pressure at each ankle to the maximal brachial systolic pressure, a pathological index being defined for a ratio < 0.90. The ABI were calculated in 219 consecutive patients (aged 55 19 years) with systolic blood pressure measured either by using a mercury sphygmomanometer and a continuous-wave Doppler probe or an automatic manometer Omron M4. This device has been validated for measurements in upper limbs, and so the authors undertook validation in the lower limbs versus intraarterial measurements. There was an excellent correlation between intraarterial measurements and automatic readings in the range of 70-220 mm Hg, r = 0.99, p < 0.001. The systolic pressures measured in upper limbs correlated well in the right (r = 0.87, p < 0.001) and the left (r = 0.89, p < 0.001) upper limbs; and in the left (r = 0.72, p < 0.001) and the right (r = 0.68, p < 0.001) lower limbs. Correlations between ABI in both methods were good in the left (r = 0.66, p < 0.001) and the right(r = 0.61, p < 0.001) lower limbs. The sensitivity (76%), specificity (95%), positive predictive value (86%), negative predictive value (90%), and global accuracy (89%) of a pathological automatic index to predict an abnormal Doppler index were good. The use of a simple, automatic blood pressure device to determine ABI appears feasible, easy, and precise. It would provide a practical tool for physicians not trained in Doppler to detect PAD.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 18 条
[1]  
Blebea J, 1997, ARCH SURG-CHICAGO, V132, P286
[2]   THE PREVALENCE OF PERIPHERAL ARTERIAL-DISEASE IN A DEFINED POPULATION [J].
CRIQUI, MH ;
FRONEK, A ;
BARRETTCONNOR, E ;
KLAUBER, MR ;
GABRIEL, S ;
GOODMAN, D .
CIRCULATION, 1985, 71 (03) :510-515
[3]   MORTALITY OVER A PERIOD OF 10 YEARS IN PATIENTS WITH PERIPHERAL ARTERIAL-DISEASE [J].
CRIQUI, MH ;
LANGER, RD ;
FRONEK, A ;
FEIGELSON, HS ;
KLAUBER, MR ;
MCCANN, TJ ;
BROWNER, D .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (06) :381-386
[4]  
CRIQUI MH, 1995, CIRCULATION, V22, P768
[5]  
DAVEYSMITH G, 1990, CIRCULATION, V82, P1925
[6]   VALIDATION OF PORTABLE NONINVASIVE BLOOD-PRESSURE MONITORING DEVICES - COMPARISONS WITH INTRA-ARTERIAL AND SPHYGMOMANOMETER MEASUREMENTS [J].
GRAETTINGER, WF ;
LIPSON, JL ;
CHEUNG, DG ;
WEBER, MA .
AMERICAN HEART JOURNAL, 1988, 116 (04) :1155-1160
[7]   Incidence, natural history and cardiovascular events in symptomatic and asymptomatic peripheral arterial disease in the general population [J].
Leng, GC ;
Lee, AJ ;
Fowkes, FGR ;
Whiteman, M ;
Dunbar, J ;
Housley, E ;
Ruckley, CV .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1996, 25 (06) :1172-1181
[8]   THE RATIO OF ANKLE AND ARM ARTERIAL-PRESSURE AS AN INDEPENDENT PREDICTOR OF MORTALITY [J].
MCKENNA, M ;
WOLFSON, S ;
KULLER, L .
ATHEROSCLEROSIS, 1991, 87 (2-3) :119-128
[9]   Peripheral arterial disease in the elderly - The Rotterdam study [J].
Meijer, WT ;
Hoes, AW ;
Rutgers, D ;
Bots, ML ;
Hofman, A ;
Grobbee, DE .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1998, 18 (02) :185-192
[10]  
Murabito JM, 1997, CIRCULATION, V96, P44