Validation of a high-performance thin-layer chromatography/densitometry method for the quantitative determination of glucosamine in a herbal dietary supplement

被引:26
作者
Esters, V
Angenot, L
Brandt, V
Frédérich, M
Tits, M
Van Nerum, C
Wauters, JN
Hubert, P
机构
[1] Univ Liege, CHU, Dept Pharm, Lab Pharmacognosy, B-4000 Cointe Ougree, Belgium
[2] Ortis Labs, B-4750 Elsenborn, Belgium
[3] Univ Liege, CHU, Dept Pharm, Analyt Chem Lab, B-4000 Cointe Ougree, Belgium
关键词
glucosamine; HPTLC; quantitative determination; validation protocol; accuracy profile;
D O I
10.1016/j.chroma.2006.01.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative densitometric high-performance thin-layer chromatography (HPTLC) method was developed for the determination of glucosamine in a dietary supplement containing dried extracts of the main plants traditionally used for rheumatic disorders. The HPTLC method was chosen in order to circumvent the tedious and time-consuming sample preparation steps necessarily performed before using HPLC methods when analysing complex matrixes. Glucosamine was separated from the plant extracts on a silica gel 60 F-254 HPTLC plate using a saturated mixture of 2-propanol-ethyl acetate-ammonia solution (8%) (10:10:10, v/v/v). The plates were developed vertically up to a distance of 80mm. For visualization, the plate was dipped into a modified anisaldehyde reagent and heated at 120 degrees C for 30 min in a drying oven. Glucosamine appeared as brownish-red chromatographic zones on a colourless background. Densitometric quantification was performed at lambda = 415 nm by reflectance scanning. The HPTLC method was successfully validated by applying the novel validation protocol proposed by a commission of the "Societe Francaise des Sciences et Techniques Pharmaccutiques" (SFSTP). In the pre-validation phase, the appropriate response function was determined, while in the validation phase the method showed good performance thereby fulfilling its objective of quantifying accurately. The relative standard deviations for repeatability and intermediate precision were between 4.9 and 8.6%. Moreover, the method was found to be accurate, as the two-sided 95% beta-expectation tolerance interval did not exceed the acceptance limits of 85 and 115% on the whole analytical range (800-1200 ng of glucosamine). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 30 条
[1]  
Aghazadeh-Habashi A, 2002, J PHARM PHARM SCI, V5, P176
[2]  
[Anonymous], 57251 ISO
[3]  
[Anonymous], 1996, INT C HARM TECHN REQ
[4]  
[Anonymous], 2001, COCHRANE DB SYST REV
[5]   Fast determination of colchicine by TLC-densitometry from pharmaceuticals and vegetal extracts [J].
Bodoki, E ;
Oprean, R ;
Vlase, L ;
Tamas, M ;
Sandulescu, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) :971-977
[6]   An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progresses and limitations [J].
Boulanger, B ;
Chiap, P ;
Dewe, W ;
Crommen, J ;
Hubert, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :753-765
[7]   Improved high-performance liquid chromatographic method to estimate aminosugars and its application to glycosaminoglycan determination in plasma and serum [J].
Campo, GM ;
Campo, S ;
Ferlazzo, AM ;
Vinci, R ;
Calatroni, A .
JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02) :151-160
[8]  
*CDER CBER FOOD DR, 2001, GUID IND BIOAN METH
[9]   Randomized, double-blind, placebo-controlled glucosamine discontinuation trial in knee osteoarthritis [J].
Cibere, J ;
Kopec, JA ;
Thorne, A ;
Singer, J ;
Canvin, J ;
Robinson, DB ;
Pope, J ;
Hong, P ;
Grant, E ;
Esdaile, JM .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2004, 51 (05) :738-745
[10]   GLUCOSAMINE OLIGOMERS .1. PREPARATION AND CHARACTERIZATION [J].
DOMARD, A ;
CARTIER, N .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 1989, 11 (05) :297-302