Assessment of the arteriovenous cerebrovascular system by multi-slice CT -: A single-bolus, monophasic protocol

被引:8
作者
Klingebiel, R
Zimmer, C
Rogalla, P
Kivelitz, D
Bohner, G
Götze, R
Lehmann, R
机构
[1] Humboldt Univ, Charite CM, Dept Neuroradiol, Inst Radiol,Neuroradiol Sect, DE-10098 Berlin, Germany
[2] Humboldt Univ, Charite CM, Dept Radiol, DE-10098 Berlin, Germany
关键词
cerebrovascular disease; assessment; CT angiography; multislice;
D O I
10.1034/j.1600-0455.2001.420605.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We present a protocol for the non-invasive angiographic assessment of the arterial and venous cerebrovascular (CV) system by multi-slice CT. Material and Methods: Data acquisition was performed in a multi-slice CT scanner with a scan range from the carotid bifurcation to the vertex and manual scan start following i.v. administration of 120 ml iodinated contrast medium with a flow rate of 4 ml/s. This protocol was applied in 12 patients with symptoms of acute CV insuffiency. Results: In all patients, comprehensive imaging of the arteriovenous CV system was achieved including the common carotid bifurcation, the third segment of the major cerebral arteries. the dural sinus and the internal cerebral veins. Various CV pathologies, such as a territorial artery occlusion, a thrombotic obstruction of the internal carotid artery, an intracranial arteriovenous malformation and a sinus vein thrombosis, were successfully evaluated. Conclusion: Comprehensive assessment of the arteriovenous CV system is possible by the use of a single-bolus. monophasic multi-slice scan technique.
引用
收藏
页码:560 / 562
页数:3
相关论文
共 16 条
  • [1] Ayanzen RH, 2000, AM J NEURORADIOL, V21, P74
  • [2] Diagnosis of cerebral venous thrombosis with routine magnetic resonance: An update
    Bianchi, D
    Maeder, P
    Bogousslavsky, J
    Schnyder, P
    Meuli, RA
    [J]. EUROPEAN NEUROLOGY, 1998, 40 (04) : 179 - 190
  • [3] Cerebral CT venography
    Casey, SO
    Alberico, RA
    Patel, M
    Jimenez, JM
    Ozsvath, RR
    Maguire, WM
    Taylor, ML
    [J]. RADIOLOGY, 1996, 198 (01) : 163 - 170
  • [4] Radiation exposure of the ocular lens and thyroid gland during digital subtraction angiography of arteries supplying the brain.
    Heyne, JP
    Schleicher, C
    Soldner, J
    Neumann, R
    Kaiser, WA
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (05): : 479 - 485
  • [5] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    [J]. MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [6] CT angiography of the cerebral veins.
    Kirchhof, K
    Jansen, O
    Sartor, K
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (03): : 232 - 237
  • [7] Knauth M, 1997, AM J NEURORADIOL, V18, P1001
  • [8] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2223 - 2230
  • [9] Cerebral venography: Comparison of CT and MR projection venography
    Ozsvath, RR
    Casey, SO
    Lustrin, ES
    Alberico, RA
    Hassankhani, A
    Patel, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) : 1699 - 1707
  • [10] Multislice CT angiography
    Prokop, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 86 - 96