Automated high resolution mass spectrometry for the synthetic chemist

被引:18
作者
Perkins, G [1 ]
Pullen, F [1 ]
Thompson, C [1 ]
机构
[1] Pfizer Ltd, Cent Res, Sandwich CT13 9NJ, Kent, England
关键词
D O I
10.1016/S1044-0305(99)00014-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exact mass measurement at high resolution is an important tool alongside other spectroscopic methods to help confirm the structure of a novel compound prepared by the synthetic chemist. Exact mass measurement is used in the pharmaceutical industry to confirm the expected empirical formula of a product when problems have been experienced using elemental analysis. Because of the amount of manual intervention necessary when acquiring exact mass measurements, especially when using probe ionization techniques such as fast atom bombardment ionization or electron ionization, this method has been seen to be time consuming and labor intensive for the mass spectrometrist. An automated high resolution mass spectrometric method has been developed at Pfizer Central Research which has streamlined exact mass measurement. The method, which uses electrospray ionization on a double focusing mass spectrometer, is described. The samples are analyzed using a flow injection technique, with sodiated polyethylene glycol present in the mobile phase to provide mass reference peaks. The data are acquired and processed using a macro developed "in house." This automated technique can process 15-20 samples an hour including data processing and report generation, using very small amounts of compound (similar to 25 mu g), but more importantly it can be left to run unattended overnight. This allows the instrument to be used for more complex experiments during the day when it is important to have a mass spectrometrist present. The results presented here demonstrate that this method gives exact mass measurements within an acceptable Limit of 5 ppm, and the variation on one sample, injected 10 times, is not excessively high (-1.8 to +1.6 mDa). (C) 1999 American Society for Mass Spectrometry.
引用
收藏
页码:546 / 551
页数:6
相关论文
共 14 条
[1]  
BOWEN DV, 1994, RAPID COMMUN MASS SP, V8, P632
[2]  
CHAPMAN JR, 1986, PRACTICAL ORGANIC MA
[3]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTROMETRY WITH A MAGNETIC-SECTOR INSTRUMENT - ACCURATE MASS MEASUREMENT AND PEPTIDE SEQUENCING [J].
DAGOSTINO, PA ;
HANCOCK, JR ;
PROVOST, LR ;
SEMCHUK, PD ;
HODGES, RS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (07) :597-603
[4]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[5]  
KLOHR SE, 1996, P 44 ANN ASMS C MASS, P656
[6]   AN ELECTROSPRAY ION-SOURCE FOR MAGNETIC-SECTOR MASS SPECTROMETERS [J].
LARSEN, BS ;
MCEWEN, CN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) :205-211
[7]   Experimental and computational approaches to estimate solubility and permeability in drug discovery and development settings [J].
Lipinski, CA ;
Lombardo, F ;
Dominy, BW ;
Feeney, PJ .
ADVANCED DRUG DELIVERY REVIEWS, 1997, 23 (1-3) :3-25
[8]   INTERPRETING MASS-SPECTRA OF MULTIPLY CHARGED IONS [J].
MANN, M ;
MENG, CK ;
FENN, JB .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1702-1708
[9]  
McLafferty F W, 1982, MASS SPECTRAL CORREL
[10]  
MOORE C, 1996, P 44 ANN ASM C MASS, P657