Pattern of osteolysis around two different cementless metal-backed cups - Retrospective, radiographic analysis at minimum 10-year follow-up

被引:41
作者
Claus, AM [1 ]
Sychterz, CJ [1 ]
Hopper, RH [1 ]
Engh, CA [1 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
关键词
osteolytic lesions; pelvic osteolysis; metal-backed shells; cementless acetabular cups; retroacetabular lysis;
D O I
10.1054/arth.2001.28365
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In this retrospective study, we analyzed the formation of osteolysis with 2 cementless cups to evaluate if surface holes in metal shells influence the radiographic pattern of osteolysis. At a minimum of 10 years' follow-up, serial radiographs of 112 hips with Arthropor cups (having multiple shell holes) and 126 hips with Anatomic Medullary Locking (AML) cups (with no holes) were reviewed. Despite differences in variables other than cup design that can affect polyethylene wear and osteolysis rates, the incidence of osteolysis between the groups was coincidentally similar (47.3%, Arthropor; 47.6%, A-ML). The time of onset of osteolysis (mean, 7.5 and 7.4 years) also was similar. The radiographic pattern of the osteolytic lesions, which is largely a factor of cup design, differed. The Arthropor group had significantly larger lesions in Charnley zone I and significantly more hips with retroacetabular lesions (Charnley zones I and II); however, these lesions did not compromise cup stability. Patients with AML cups had more and larger lesions in the greater trochanter.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 30 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
Wear and osteolysis in total joint replacements [J].
Aspenberg, P ;
Kadoya, Y ;
Kobayashi, A ;
Ohashi, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (04) :435-436
[3]
BERGER RA, 1997, CLIN ORTHOP RELAT R, V344, P2166
[4]
Bilobed oblong porous coated acetabular components in revision total hip arthroplasty [J].
Berry, DJ ;
Sutherland, CJ ;
Trousdale, RT ;
Colwell, CW ;
Chandler, HP ;
Ayres, D ;
Yashar, AA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (371) :154-160
[5]
Wear of retrieved cemented polyethylene acetabula with alumina femoral heads [J].
Bragdon, CR ;
Jasty, M ;
Kawate, K ;
McGrory, BJ ;
Elder, JR ;
Lowenstein, J ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1997, 12 (02) :119-125
[6]
Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[7]
DAVEY JR, 1988, CLIN ORTHOP RELAT R, P97
[8]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]
DEVANE PA, 1997, T 43 ANN M ORTH RES
[10]
Engh C.A., 1985, BIOL FIXATION TOTAL