Sutureless securement device reduces complications of peripherally inserted central venous catheters

被引:189
作者
Yamamoto, AJ
Solomon, JA
Soulen, MC
Tang, J
Parkinson, K
Lin, R
Schears, GJ
机构
[1] Hosp Univ Penn, Div Interventional Radiol, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Dept Anesthesia & Crit Care Med, Philadelphia, PA USA
关键词
catheters and catheterization; central venous access;
D O I
10.1016/S1051-0443(07)60012-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: This study was conducted to evaluate the performance of a sutureless adhesive-backed device, StatLock, for securement of peripherally inserted central venous catheters (PICCs). Earlier studies have demonstrated that StatLock significantly reduces catheter-related complications when compared to tape. The purpose of this study was to determine whether a sutureless securement device offers an advantage over suture in preventing catheter-related complications. MATERIALS AND METHODS: 170 patients requiring PICCs, which were randomized to suture (n = 85) or StatLock (n = 85) securement were prospectively studied. Patients were followed throughout their entire catheter course, and PICC-related complications including dislodgment, infection, occlusion, leakage, and central venous thrombosis were documented. Catheter outcome data were compared to determine if statistically significant differences existed between the suture and StatLock groups. RESULTS: The groups had equivalent demographic characteristics and catheter indications. Average securement time with StatLock was significantly shorter (4.7 minutes vs 2.7 minutes; P < .001). Although StatLock was associated with fewer total complications (42 vs 61), this difference did not achieve significance. However, there were significantly fewer PICC-related bloodstream infections in the StatLock group (2 vs 10; P = .032). One securement-related needle-stick injury was documented during suturing of a PICC. CONCLUSION: The sutureless anchor pad was beneficial for both patients and health care providers. Further investigation to determine how StatLock helps reduce catheter-related blood stream infections is necessary.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 14 条
[1]  
[Anonymous], STATLOCK CATHETER SE
[2]  
Cardella J F, 1993, J Vasc Interv Radiol, V4, P653, DOI 10.1016/S1051-0443(93)71941-7
[3]   Cumulative experience with 1,273 peripherally inserted central catheters at a single institution [J].
Cardella, JF ;
Cardella, K ;
Bacci, N ;
Fox, PS ;
Post, JH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (01) :5-13
[4]  
Goodwin M L, 1993, J Intraven Nurs, V16, P92
[5]  
MCGREER A, 1990, J INFECT DIS, V172, P961
[6]   Prevention of intravascular catheter-related infections [J].
Mermel, LA .
ANNALS OF INTERNAL MEDICINE, 2000, 132 (05) :391-402
[7]  
Miller K D, 1997, J Intraven Nurs, V20, P141
[8]  
MORO ML, 1994, INFECT CONT HOSP EP, V15, P253
[9]   Peripherally inserted central catheters in general medicine [J].
Ng, PK ;
Ault, MJ ;
Ellrodt, AG ;
Maldonado, L .
MAYO CLINIC PROCEEDINGS, 1997, 72 (03) :225-233
[10]   Device-specific sharps injury and usage rates: An analysis by hospital department [J].
Patel, N ;
Tignor, GH .
AMERICAN JOURNAL OF INFECTION CONTROL, 1997, 25 (02) :77-84