Mechanical ventilation with or without daily changes of in-line suction catheters

被引:83
作者
Kollef, MH
Prentice, D
Shapiro, SD
Fraser, VJ
Silver, P
Trovillion, E
Weilitz, P
VonHarz, B
StJohn, R
机构
[1] WASHINGTON UNIV, SCH MED, DIV INFECT DIS, ST LOUIS, MO 63110 USA
[2] BARNES JEWISH HOSP, DEPT RESP THERAPY, ST LOUIS, MO 63110 USA
[3] BARNES JEWISH HOSP, DEPT NURSING, ST LOUIS, MO 63110 USA
[4] BARNES JEWISH HOSP, DEPT INFECT CONTROL, ST LOUIS, MO 63110 USA
关键词
D O I
10.1164/ajrccm.156.2.9612083
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The purpose of this study was to determine the safety and cost-effectiveness of not routinely changing in-line suction catheters for patients requiring mechanical ventilation. Patients were randomly assigned to receive either no routine in-line suction catheter changes (n = 258) or in-line suction catheter changes every 24 h (n = 263). The main outcome measure was the incidence of ventilator-associated pneumonia. Other outcomes evaluated included hospital mortality, acquired organ system derangements, duration of mechanical ventilation, lengths of intensive care and hospital stay, and the cost for in-line suction catheters. Ventilator-associated pneumonia was seen in 38 patients (14.7%) receiving no routine in-line suction catheter changes and in 39 patients (14.8%) receiving inline suction catheter changes every 24 h (relative risk, 0.99; 95% CI, 0.66 to 1.50). No statistically significant differences for hospital mortality, lengths of stay, the number of acquired organ system derangements, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups. Patients receiving in-line suction catheter changes every 24 h had 1,224 catheter changes costing a total of $11,016; patients receiving no routine in-line suction catheter changes had a total of 93 catheter changes costing $837. Our findings suggest that the elimination of routine in-line suction catheter changes is safe and can reduce the costs associated with providing mechanical ventilation.
引用
收藏
页码:466 / 472
页数:7
相关论文
共 35 条
[1]   NOSOCOMIAL PNEUMONIA IN MEDICARE PATIENTS - HOSPITAL COSTS AND REIMBURSEMENT PATTERNS UNDER THE PROSPECTIVE PAYMENT SYSTEM [J].
BOYCE, JM ;
POTTERBYNOE, G ;
DZIOBEK, L ;
SOLOMON, SL .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (06) :1109-1114
[2]   INVASIVE DIAGNOSTIC TESTING SHOULD BE ROUTINELY USED TO MANAGE VENTILATED PATIENTS WITH SUSPECTED PNEUMONIA [J].
CHASTRE, J ;
FAGON, JY .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :570-574
[3]   ENVIRONMENTAL CONTAMINATION DURING TRACHEAL SUCTION - A COMPARISON OF DISPOSABLE CONVENTIONAL CATHETERS WITH A MULTIPLE-USE CLOSED SYSTEM DEVICE [J].
COBLEY, M ;
ATKINS, M ;
JONES, PL .
ANAESTHESIA, 1991, 46 (11) :957-961
[4]   CONTAMINATION OF MECHANICAL VENTILATORS WITH TUBING CHANGES EVERY 24 OR 48 HOURS [J].
CRAVEN, DE ;
CONNOLLY, MG ;
LICHTENBERG, DA ;
PRIMEAU, PJ ;
MCCABE, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 306 (25) :1505-1509
[5]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[6]  
CRAVEN DE, 1986, AM REV RESPIR DIS, V133, P792
[7]  
DECKER MD, 1993, 3 ANN M SOC HOSP EP, pA6
[8]  
DePew C L, 1994, Crit Care Nurse, V14, P94
[9]  
DePew C L, 1994, Dimens Crit Care Nurs, V13, P73, DOI 10.1097/00003465-199403000-00004
[10]   INCIDENCE OF COLONIZATION, NOSOCOMIAL PNEUMONIA, AND MORTALITY IN CRITICALLY ILL PATIENTS USING A TRACH CARE CLOSED-SUCTION SYSTEM VERSUS AN OPEN-SUCTION SYSTEM - PROSPECTIVE, RANDOMIZED STUDY [J].
DEPPE, SA ;
KELLY, JW ;
THOI, LL ;
CHUDY, JH ;
LONGFIELD, RN ;
DUCEY, JP ;
TRUWIT, CL ;
ANTOPOL, MR .
CRITICAL CARE MEDICINE, 1990, 18 (12) :1389-1393