Hybridization behavior of mixed DNA/alkylthiol monolayers on gold:: Characterization by surface plasmon resonance and 32P radiometric assay

被引:115
作者
Gong, Ping
Lee, Chi-Ying
Gamble, Lara J.
Castner, David G.
Grainger, David W. [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
[2] Univ Washington, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[3] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[4] Univ Washington, Dept Chem Engn, Seattle, WA 98195 USA
关键词
D O I
10.1021/ac052138b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nucleic acid assay from a complex biological milieu is attractive but currently difficult and far from routine. In this study, DNA hybridization from serum dilutions into mixed DNA/mercaptoundecanol (MCU) adlayers on gold was monitored by surface plasmon resonance (SPR). Immobilized DNA probe and hybridized target densities on these surfaces were quantified using P-32-radiometric assays as a function of MCU diluent exposure. SPR surface capture results correlated with radiometric analysis for hybridization performance, demonstrating a maximum DNA hybridization on DNA/MCU mixed adlayers. The maximum target surface capture produced by MCU addition to the DNA probe layer correlates with structural and conformational data on identical mixed DNA/MCU adlayers on gold derived from XPS, NEXAFS, and fluorescence intensity measurements reported in a related study ( Lee, C.-Y.; Gong, P.; Harbers, G. M.; Grainger, D. W.; Castner, D. G.; Gamble, L. J. Anal. Chem. 2006, 78, 3316-3325.). MCU addition into the DNA adlayer on gold also improved surface resistance to both nonspecific DNA and serum protein adsorption. Target DNA hybridization from serum dilutions was monitored with SPR on the optimally mixed DNA/MCU adlayers. Both hybridization kinetics and efficiency were strongly affected by nonspecific protein adsorption from a complex milieu even at a minimal serum concentration (e.g., 1%). No target hybridization was detected in SPR assays from serum concentrations above 30%, indicating nonspecific protein adsorption interference of DNA capture and hybridization from complex milieu. Removal of nonsignal proteins from nucleic acid targets prior to assay represents a significant issue for direct sample-to-assay nucleic acid diagnostics from food, blood, tissue, PCR mixtures, and many other biologically complex sample formats.
引用
收藏
页码:3326 / 3334
页数:9
相关论文
共 45 条
[1]  
[Anonymous], 1987, Molecular Biology of the Gene
[2]   A multistep chemical modification procedure to create DNA arrays on gold surfaces for the study of protein-DNA interactions with surface plasmon resonance imaging [J].
Brockman, JM ;
Frutos, AG ;
Corn, RM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (35) :8044-8051
[3]   Characterization of grafting density and binding efficiency of DNA and proteins on gold surfaces [J].
Castelino, K ;
Kannan, B ;
Majumdar, A .
LANGMUIR, 2005, 21 (05) :1956-1961
[4]   Simulations of single grafted polyelectrolyte chains: ssDNA and dsDNA [J].
Crozier, PS ;
Stevens, MJ .
JOURNAL OF CHEMICAL PHYSICS, 2003, 118 (08) :3855-3860
[5]   SURFACE-PLASMON RESONANCE APPLIED TO IMMUNOSENSING [J].
DANIELS, PB ;
DEACON, JK ;
EDDOWES, MJ ;
PEDLEY, DG .
SENSORS AND ACTUATORS, 1988, 15 (01) :11-18
[6]  
Darnell J., 1990, Molecular Cell Biology, V2nd ed.
[7]  
Forman JE, 1998, ACS SYM SER, V682, P206
[8]   Multi-technique comparison of immobilized and hybridized oligonucleotide surface density on commercial amine-reactive microarray slides [J].
Gong, P ;
Harbers, GM ;
Grainger, DW .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2342-2351
[9]   Comparison of DNA immobilization efficiency on new and regenerated commercial amine-reactive polymer microarray surfaces [J].
Gong, P ;
Grainger, DW .
SURFACE SCIENCE, 2004, 570 (1-2) :67-77
[10]   Competitive protein adsorption as observed by surface plasmon resonance [J].
Green, RJ ;
Davies, MC ;
Roberts, CJ ;
Tendler, SJB .
BIOMATERIALS, 1999, 20 (04) :385-391