High resolution inductively coupled plasma Fourier transform ion cyclotron resonance mass spectrometry

被引:32
作者
Milgram, KE
White, FM
Goodner, KL
Watson, CH
Koppenaal, DW
Barinaga, CJ
Smith, BH
Winefordner, JD
Marshall, AG
Houk, RS
Eyler, JR
机构
[1] UNIV FLORIDA, DEPT CHEM, GAINESVILLE, FL 32611 USA
[2] FLORIDA STATE UNIV, DEPT CHEM, TALLAHASSEE, FL 32310 USA
[3] PACIFIC NW LAB, RICHLAND, WA 99352 USA
[4] NATL HIGH MAGNET FIELD LAB, TALLAHASSEE, FL 32310 USA
[5] IOWA STATE UNIV, DEPT CHEM, US DEPT ENERGY, AMES LAB, AMES, IA 50011 USA
关键词
D O I
10.1021/ac970126n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Initial results obtained by incorporation of an inductively coupled plasma (ICP) ion source with a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer are reported, along with spectra which demonstrate submilligram-per-liter detection limits and high mass resolution (mass resolving power, m/Delta m(10%V) = 7000-10 000), Also shown is an ICP-FTICR spectrum with ultrahigh resolving power (m/Delta m(10%V) = 88 000). Both instrumental configurations used to conduct this work, one at the University of Florida, and the other at the National High Magnetic Field Laboratory, are described. Also included are concise results from a computer aided interference study designed to enumerate mass spectral interferences requiring mass resolving power in excess of 10 000.
引用
收藏
页码:3714 / 3721
页数:8
相关论文
共 62 条
[1]   REDUCTION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY CRYOGENIC DESOLVATION [J].
ALVES, LC ;
WIEDERIN, DR ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1164-1169
[2]   ION-TRAP MASS-SPECTROMETRY WITH AN INDUCTIVELY-COUPLED PLASMA SOURCE [J].
BARINAGA, CJ ;
KOPPENAAL, DW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (01) :71-76
[3]  
Barinaga CJ, 1996, FRESEN J ANAL CHEM, V355, P487
[4]   A GLOW-DISCHARGE ION-SOURCE WITH FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRIC DETECTION [J].
BARSHICK, CM ;
EYLER, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (02) :122-127
[5]   AN IMPROVED ION GUIDE FOR EXTERNAL ION INJECTION IN GLOW-DISCHARGE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BARSHICK, CM ;
EYLER, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (05) :387-392
[6]   INDUCTIVELY COUPLED PLASMA AS AN ION-SOURCE FOR HIGH-RESOLUTION MASS-SPECTROMETRY [J].
BRADSHAW, N ;
HALL, EFH ;
SANDERSON, NE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :801-803
[7]  
BRUCE J, 1997, 45 ASMS C ASMS C MAS
[8]   TRAPPING, DETECTION, AND MASS MEASUREMENT OF INDIVIDUAL IONS IN A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
BRUCE, JE ;
CHENG, X ;
BAKHTIAR, R ;
WU, Q ;
HOFSTADLER, SA ;
ANDERSON, GA ;
SMITH, RD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (17) :7839-7847
[9]   ATTENUATION OF METAL-OXIDE IONS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH A GRAPHITE TORCH INJECTOR [J].
CLEMONS, PS ;
MINNICH, MG ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1929-1934
[10]  
Dienes T, 1996, MASS SPECTROM REV, V15, P163, DOI 10.1002/(SICI)1098-2787(1996)15:3<163::AID-MAS2>3.0.CO