摘要
To determine whether a derived 12-lead electrocardiogram (EGG) would demonstrate typical ST-segment changes of ischemia during percutaneous transluminal coronary angioplasty (PTCA), 207 patients were monitored with continuous 12-lead ST-segment monitoring during angioplasty. Additionally, to compare the derived and standard ECGs during known periods of ischemia with PTCA balloon inflation, 151 patients were recorded with both electrocardiographic methods during the procedure. Of the 207 patients recorded with the derived EGG, 171 (83%) had typical ischemic ST-segment changes during PTCA balloon inflation. The amplitudes of these ST deviations were similar to those observed during transient myocardial ischemia observed in clinical settings (median peak ST deviation, 225 mu V). There was agreement regarding presence or absence of ischemia in 150 of the 151 patients recorded with both derived and standard electrocardiographic methods (> 99% agreement). With use of the standard ECG as the ''gold standard'' for ischemia diagnosis, there were no false-positive results and only 1 false-negative result with the derived EGG. Furthermore, there was nearly perfect agreement between the two 12-lead methods in terms of anterior versus inferior wall patterns of ischemia. Future studies are required to determine whether continuous monitoring with a derived ECG would improve diagnosis and lead to better patient outcomes. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 12 条
[1]   12-LEAD ELECTROCARDIOGRAPHIC EVALUATION OF ISCHEMIA DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AND ITS CORRELATION WITH ACUTE REOCCLUSION [J].
BUSH, HS ;
FERGUSON, JJ ;
ANGELINI, P ;
WILLERSON, JT .
AMERICAN HEART JOURNAL, 1991, 121 (06) :1591-1599
[2]  
Dower G.E., 1996, EASI 12 LEAD ELECTRO
[3]  
DOWER GE, 1988, J ELECTROCARDIOL, pS182
[4]  
DOWER GE, 1997, IN PRESS J ELECTROCA
[5]  
Drew B J, 1996, Am J Crit Care, V5, P198
[6]   COMPARISON OF A VECTORCARDIOGRAPHICALLY DERIVED 12-LEAD ELECTROCARDIOGRAM WITH THE CONVENTIONAL ELECTROCARDIOGRAM DURING WIDE QRS COMPLEX TACHYCARDIA, AND ITS POTENTIAL APPLICATION FOR CONTINUOUS BEDSIDE MONITORING [J].
DREW, BJ ;
SCHEINMAN, MM ;
EVANS, GT .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) :612-618
[7]   AN ACCURATE, CLINICALLY PRACTICAL SYSTEM FOR SPATIAL VECTORCARDIOGRAPHY [J].
FRANK, E .
CIRCULATION, 1956, 13 (05) :737-749
[8]  
KRUCOFF M, 1988, AM J CARDIOL, V61, pF29
[9]   THE PORTABLE PROGRAMMABLE MICROPROCESSOR-DRIVEN REAL-TIME 12-LEAD ELECTROCARDIOGRAPHIC MONITOR - A PRELIMINARY-REPORT OF A NEW DEVICE FOR THE NONINVASIVE DETECTION OF SUCCESSFUL REPERFUSION OR SILENT CORONARY REOCCLUSION [J].
KRUCOFF, MW ;
WAGNER, NB ;
POPE, JE ;
MORTARA, DM ;
JACKSON, YR ;
BOTTNER, RK ;
WAGNER, GS ;
KENT, KM .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (03) :143-148
[10]   STABILITY OF MULTILEAD ST-SEGMENT FINGERPRINTS OVER TIME AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY AND ITS USEFULNESS IN DETECTING REOCCLUSION [J].
KRUCOFF, MW ;
PARENTE, AR ;
BOTTNER, RK ;
RENZI, RH ;
STARK, KS ;
SHUGOLL, RA ;
AHMED, SW ;
DEMICHELE, J ;
STROMING, SL ;
GREEN, CE ;
RACKLEY, CE ;
KENT, KM .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1232-1237