Controlling dentine penetration in computer microleakage tracer mapping

被引:15
作者
Gale, MS
Darvell, BW
机构
[1] UNIV HONG KONG,FAC DENT,DEPT CONSERVAT DENT,HONG KONG,HONG KONG
[2] UNIV HONG KONG,FAC DENT,DENT MAT SCI UNIT,HONG KONG,HONG KONG
关键词
dental materials; microleakage; interfaces; composites; dentine bonding agents;
D O I
10.1016/S0300-5712(96)00020-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Microleakage tracer penetration tests in dentine with simple sectioning are often confounded by dentine tubule penetration into the interface, leaching of water soluble tracers on wet sectioning, lack of standardized cavity dimensions affecting stresses, inadequate sectioning missing important tracer regions and airlocks obstructing tracer entry. The present aim was to create high resolution maps of stained interfaces without these confounding factors. Methods: Ten intact extracted permanent upper central incisors were horizontally sectioned through the upper root, one third of the root length from the mid-buccal enamel limit. A dentine-bonded resin composite (Scotchbond MP, Z100, 3M) restoration was placed in a cylindrical cavity milled centrally in the root face of the coronal portion of five teeth. Tubules were angled at a mean of 12.5+/-4.8 degrees to the root face, and travelled approximately radially from the interface, such that tubule penetration was directed sufficiently radially outward to be distinguished from vertical interface penetration. Waterfast silver nitrate staining was applied with initial vacuum at 30 mmHg. A precision grinding machine serially removed approximately 100 mu m increments of the tooth until no tracer remained, and computer image analysis data for the 18 revealed surfaces were used to construct detailed interface tracer maps. Results: Control specimen tubule penetration was directed sufficiently radially outward to permit tubule penetration to be isolated from vertical interface penetration in test specimens, and ignored. Interface penetration ranged from approximately 0.3 to 1.6 mm in depth, and 0.90 to 5.09 mm(2) in area. Conclusions: This method provided quantitative standardized high resolution mapping of interface tracer penetration, unconfounded by dentine penetration. None of the interfaces was fully sealed. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 27 条
[1]  
BHASKAR SN, 1986, ORBANS ORAL HISTOLOG, P101
[2]   PRINCIPLES OF ADHESIVE RETENTION AND ADHESIVE RESTORATIVE MATERIALS [J].
BUONOCORE, MG .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1963, 67 (03) :382-+
[3]   MARGINAL SEAL OF NEW-GENERATION DENTAL BONDING AGENTS [J].
CHAN, KC ;
SWIFT, EJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (04) :420-423
[4]   SIGNIFICANCE OF THERMAL CYCLING IN MICROLEAKAGE ANALYSIS OF ROOT RESTORATIONS [J].
CHAN, MFWY ;
JONES, JCG .
JOURNAL OF DENTISTRY, 1994, 22 (05) :292-295
[5]   MICROLEAKAGE COMPARISON OF DENTIN BONDING SYSTEMS WITH GLASS IONOMER [J].
CHOHAYEB, AA .
DENTAL MATERIALS, 1992, 8 (01) :27-30
[6]  
Duke E S, 1993, Dent Clin North Am, V37, P329
[7]   CLINICAL RELEVANCE OF THE FORMULATION AND TESTING OF DENTIN BONDING SYSTEMS [J].
ELIADES, G .
JOURNAL OF DENTISTRY, 1994, 22 (02) :73-81
[8]   3-DIMENSIONAL RECONSTRUCTION OF MICROLEAKAGE PATTERN USING A SEQUENTIAL GRINDING TECHNIQUE [J].
GALE, MS ;
DARVELL, BW ;
CHEUNG, GSP .
JOURNAL OF DENTISTRY, 1994, 22 (06) :370-375
[9]  
Garcia-Godoy F., 1993, Journal of Dental Research, V72, P308
[10]   MICROLEAKAGE IN 3 DESIGNS OF GLASS IONOMER UNDER COMPOSITE RESIN RESTORATIONS [J].
GORDON, M ;
WASSERSTEIN, A ;
GORFIL, C ;
IMBER, S .
JOURNAL OF ORAL REHABILITATION, 1991, 18 (02) :149-154