A new device for the measurement of disease severity in patients with intermittent claudication

被引:9
作者
Coughlin, PA [1 ]
Kent, PJ [1 ]
Turton, EP [1 ]
Byrne, P [1 ]
Berridge, DC [1 ]
Scott, DJ [1 ]
Kester, RC [1 ]
机构
[1] St James Univ Hosp, Dept Vasc & Endovasc Surg, Leeds LS9 7TF, W Yorkshire, England
关键词
PADHOC; intermittent claudication; treadmill;
D O I
10.1053/ejvs.2001.1528
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to, assess a new method of determining, functional impairment in patients with intermittent claudication, the. Double Physiological Walking Test (DPWT) using the PADHOC (Peripheral Arterial Disease Holter Control) device, against a standard treadmill test. Design:, patients with intermittent claudication presenting to the department were considered for both the DPWT and a standard treadmill test, Methods: initial claudicating distance. maximal walking distance and speed of walking were determined for both parts of the DPWT. Initial claudicating distance and maximal walking distance were determined from the treadmill test. Comparisons were made between the treadmill test and the DPWT. Results: the treadmill test was unable to be performed in 22% of patients due to defined contraindications. There were, strong correlations in both walking distances and disease severity when comparing the DPWT and the treadmill test. Patients in whom the treadmill test was contraindicated had significantly shorter walking distances on the DPWT than those who were able to complete a treadmill walking test. Conclusions: the DPWT correlates strongly with walking distances obtained from a standard treadmill test. However, the PADHOC can be used in a number of differing locations and settings as well as in patients in whom a treadmill test is contraindicated. It therefore has a role to play in the initial assessment of patients presenting with intermittent claudication.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 17 条
[1]   COVARIATION BETWEEN WALKING ABILITY AND CIRCULATORY ALTERATIONS IN PATIENTS WITH INTERMITTENT CLAUDICATION [J].
ARFVIDSSON, B ;
WENNMALM, A ;
GELIN, J ;
DAHLLOF, AG ;
HALLGREN, B ;
LUNDHOLM, K .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (06) :642-646
[2]  
Boissier C, 1997, DIS MANAG HLTH OU S1, V2, P57
[3]   Randomized reliability study evaluating constant-load and graded-exercise treadmill test for intermittent claudication [J].
Cachovan, M ;
Rogatti, W ;
Woltering, F ;
Creutzig, A ;
Diehm, C ;
Heidrich, H ;
Scheffler, P .
ANGIOLOGY, 1999, 50 (03) :193-200
[4]   The Stresst'er ergometer as an alternative to treadmill testing in patients with claudication [J].
Cameron, AEP ;
Porter, A ;
Rosser, S ;
Da Silva, AECF ;
De Cossart, LM .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (06) :433-438
[5]   Percutaneous transluminal angioplasty for intermittent claudication: Evidence on which to base the medicine [J].
Chetter, IC ;
Spark, JI ;
Kent, PJ ;
Berridge, DC ;
Scott, DJA ;
Kester, RC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (06) :477-484
[6]   Estimation of walking distance in intermittent claudication: need for standardization [J].
Duprez, D ;
De Backer, T ;
De Buyzere, M ;
Clement, DL .
EUROPEAN HEART JOURNAL, 1999, 20 (09) :641-644
[7]  
Gardner AW, 1998, ANGIOLOGY, V49, P723
[8]   EFFECTS OF HANDRAIL SUPPORT ON CLAUDICATION AND HEMODYNAMIC-RESPONSES TO SINGLE-STAGE AND PROGRESSIVE TREADMILL PROTOCOLS IN PERIPHERAL VASCULAR OCCLUSIVE DISEASE [J].
GARDNER, AW ;
SKINNER, JS ;
SMITH, LK .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (01) :99-105
[9]   Reliability of treadmill testing in peripheral arterial disease: a comparison of a constant load with a graded load treadmill protocol [J].
Labs, KH ;
Nehler, MR ;
Roessner, M ;
Jaeger, KA ;
Hiatt, WR .
VASCULAR MEDICINE, 1999, 4 (04) :239-246
[10]  
LAING S, 1986, INT ANGIOL, V5, P249