Comparative analysis of aortic impedance and wave reflection in ferrets and dogs

被引:9
作者
Burattini, R
Campbell, KB
机构
[1] Univ Ancona, Dept Elect & Automat, I-60131 Ancona, Italy
[2] Washington State Univ, Dept Vet & Comparat Anat Pharmacol & Physiol, Pullman, WA 99164 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2002年 / 282卷 / 01期
关键词
arterial pulse wave propagation; arterial effective reflection sites; arterial compliance; T-tube arterial model;
D O I
10.1152/ajpheart.2002.282.1.H244
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Our modified version of the T-tube arterial model (consisting of two parallel, loss-free transmission paths terminating in lumped loads of complex and frequency-dependent nature) was applied to experimental measurements of ascending aortic pressure and of ascending and descending aortic flows taken from dogs and ferrets. Our aim was to provide quantitative evaluation of the aortic pressure and flow pulse wave components as they relate to the distribution of arterial properties and relate to wave travel and reflection in mammalians of consistently different size and shape. Estimated effective lengths (distances to effective reflection sites) of the head-end (d(h)) and body-end (d(b)) transmission paths were similar to 12 and 30 cm, respectively, in the dog and 6.5 and 13 cm, respectively, in the ferret. These lengths and distributions of estimated arterial properties were consistent with the difference in the body size and with the more central location of the heart in the ferret's body than it is in the dog's body. In both animal species the ascending aortic pressure and flow waves could be interpreted in terms of forward and reflected components arising from the two distinct effective reflection sites, although the higher d(h)/d(b) ratio in the ferret determined the presence of one broad, indistinct minimum in the modulus of ascending aortic impedance in the frequency range from 0 to 10 Hz, rather than two distinct minima as observed in the dog.
引用
收藏
页码:H244 / H255
页数:12
相关论文
共 30 条
[1]  
[Anonymous], 1968, GRUNDLAGEN DYNAMIK A
[2]   COMPARATIVE-STUDY OF PULSATILE ARTERIAL HEMODYNAMICS IN RABBITS AND GUINEA-PIGS [J].
AVOLIO, AP ;
OROURKE, MF ;
MANG, K ;
BASON, PT ;
GOW, BS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1976, 230 (04) :868-875
[3]  
Bard Y., 1974, Nonlinear Parameter Estimation
[4]   Complex and frequency-dependent compliance of viscoelastic windkessel resolves contradictions in elastic windkessels [J].
Burattini, R ;
Natalucci, S .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (07) :502-514
[5]   2 ARTERIAL EFFECTIVE REFLECTING SITES MAY APPEAR AS ONE TO THE HEART [J].
BURATTINI, R ;
KNOWLEN, GG ;
CAMPBELL, KB .
CIRCULATION RESEARCH, 1991, 68 (01) :85-99
[6]   A SIMPLE ALGORITHM FOR DEFINING THE MEAN CARDIAC CYCLE OF AORTIC FLOW AND PRESSURE DURING STEADY-STATE [J].
BURATTINI, R ;
FIORETTI, S ;
JETTO, L .
COMPUTERS AND BIOMEDICAL RESEARCH, 1985, 18 (04) :303-312
[7]   EFFECTIVE LENGTH OF THE ARTERIAL CIRCULATION DETERMINED IN THE DOG BY AID OF A MODEL OF THE SYSTEMIC INPUT IMPEDANCE [J].
BURATTINI, R ;
DICARLO, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (01) :53-61
[8]   EFFECTIVE DISTRIBUTED COMPLIANCE OF THE CANINE DESCENDING AORTA ESTIMATED BY MODIFIED T-TUBE MODEL [J].
BURATTINI, R ;
CAMPBELL, KB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06) :H1977-H1987
[9]   Physiological relevance of uniform elastic tube-models to infer descending aortic wave reflection: A problem of identifiability [J].
Burattini, R ;
Campbell, KB .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (05) :512-523
[10]   MODIFIED ASYMMETRIC T-TUBE MODEL TO INFER ARTERIAL WAVE REFLECTION AT THE AORTIC ROOT [J].
BURATTINI, R ;
CAMPBELL, KB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (08) :805-814