Assessment of cardiac wall motion and ejection fraction with gated PET using n-13 ammonia

被引:30
作者
Hickey, KT
Sciacca, RR
Bokhari, S
Rodriguez, O
Chou, RL
Faber, TL
Cooke, CD
Garcia, EV
Nichols, K
Bergmann, SR
机构
[1] Columbia Univ Coll Phys & Surg, Div Cardiol, Dept Med, New York, NY 10034 USA
[2] Emory Univ, Dept Radiol, Div Nucl Med Res, Atlanta, GA 30322 USA
关键词
positron emission tomography; nitrogen-13; ammonia; gating; myocardial perfusion imaging;
D O I
10.1097/01.rlu.0000118001.14457.c3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cardiac gating is not routinely used in cardiac positron emission tomography (PET). The aim of this study was to determine the feasibility of assessing regional wall motion, ejection fraction (EF). cardiac volumes, and mass with nitrogen-13 ammonia (N-13 ammonia) at the time of PET myocardial perfusion imaging. Methods: We studied 12 healthy volunteers (mean age, 28 +/- 8 years) and 53 patients with documented coronary artery disease (CAD) (mean age, 59 +/- 11 years). All subjects received a single administration of approximately 600 MBq (16 mCi) of N-13 ammonia intravenously. A 6-minute dynamic scan was performed for quantitative assessment of myocardial perfusion at rest, followed by a separate, 13-minute static scan acquired in the gated mode (8 equal bins). Gated data was imported into the Emory Toolbox. Wall motion was evaluated by dividing the myocardium into 9 anatomic regions graded semiquantitatively. Results: Healthy volunteers had a normal EF (61 +/- 6), end systolic volume (ESV) (37 +/- 15 mL), end diastolic volume (EDV) (89 +/- 25 mL), and cardiac mass (116 +/- 18 g). In contrast, patients with CAD showed reduced EF (32 +/- 13%) and increased ESV (129 +/- 56 mL), EDV (188 +/- 68 mL). and cardiac mass (173 +/- 45g) (P < 0.001 for each). In patients with CAD, EF measured by gated PET correlated significantly to independent measurements of EF (P < 0.001). Conclusions: Gating of cardiac perfusion images obtained after administration of N-13 ammonia is feasible and appears to be an accurate means of evaluating regional and global cardiac function. Gating can
引用
收藏
页码:243 / 248
页数:6
相关论文
共 22 条
[1]   Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: Influence of tracer, gender, and acquisition camera [J].
Ababneh, AA ;
Sciacca, RR ;
Kim, B ;
Bergmann, SR .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) :661-668
[2]   Gated single-photon emission computed tomographic myocardial imaging: A new tool in clinical cardiology [J].
Bavelaar-Croon, CDL ;
Pauwels, EKJ ;
van der Wall, EE .
AMERICAN HEART JOURNAL, 2001, 141 (03) :383-390
[3]   HETEROGENEITY OF REGIONAL NITROGEN 13-LABELED AMMONIA TRACER DISTRIBUTION IN THE NORMAL HUMAN HEART - COMPARISON WITH RUBIDIUM-82 AND COPPER-62-LABELED PTSM [J].
BEANLANDS, RSB ;
MUZIK, O ;
HUTCHINS, GD ;
WOLFE, ER ;
SCHWAIGER, M .
JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (03) :225-235
[4]   Cardiac positron emission tomography [J].
Bergmann, SR .
SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (04) :320-340
[5]  
BERGMANN SR, 1997, CARDIAC NUCL MED, P267
[6]  
BERGMANN SR, 1992, POSITRON EMISSION TO, P97
[7]   Evaluation of ventricular ejection fraction, wall motion, wall thickening, and other parameters with gated myocardial perfusion single-photon emission computed tomography [J].
Berman, DS ;
Germano, G .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (02) :S169-S171
[8]  
DEPUEY E, 1995, J NUCL MED, V36, P952
[9]   Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT [J].
DePuey, EG ;
Parmett, S ;
Ghesani, M ;
Rozanski, A ;
Nichols, K ;
Salensky, H .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (03) :278-285
[10]  
DEPUEY EG, 1993, J NUCL MED, V34, P1871