Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging

被引:62
作者
Brossmann, J
Frank, LR
Pauly, JM
Boutin, RD
Pedowitz, RA
Haghighi, P
Resnick, D
机构
[1] VET ADM MED CTR, DEPT RADIOL, SAN DIEGO, CA 92161 USA
[2] VET ADM MED CTR, DEPT ORTHOPED SURG, SAN DIEGO, CA 92161 USA
[3] VET ADM MED CTR, DEPT PATHOL & LAB MED, SAN DIEGO, CA 92161 USA
[4] STANFORD UNIV, INFORMAT SYST LAB, DEPT ELECT ENGN, STANFORD, CA 94305 USA
关键词
cartilage; joints; MR; knee; magnetic resonance (MR); comparative studies; technology; patella;
D O I
10.1148/radiology.203.2.9114112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate short echo time (TE) projection reconstruction magnetic resonance (MR) imaging in the detection of cartilage lesions. MATERIALS AND METHODS: Twenty-seven cartilage regions of 10 human patellar specimens were examined with the following MR sequences: short TE projection reconstruction (repetition time msec/TE msec, 400/0.15), fat-suppressed three-dimensional spoiled gradient-recalled acquisition in the steady state (Spoiled GRASS) (50/10, 60 degrees flip angle), and magnetization transfer contrast (MTC) subtraction (400/6). MR findings were correlated with histopathologic grading of the cartilage. RESULTS: For detection of cartilage lesions, sensitivity of projection reconstruction imaging (100%) was significantly greater (P = .03) than that of MTC (62%) but not significantly greater (P > .05) than that of Spoiled GRASS (81%) imaging. Accuracy of projection reconstruction was significantly greater than that of MTC (P .004) and Spoiled GRASS (P = .03) imaging. Unmasking of collagen fibers was most predictive of abnormal signal intensity of the cartilage with all sequences. CONCLUSION: In vitro, short TE projection reconstruction MR imaging provides superior delineation of cartilage lesions when compared with two other sequences. On Spoiled GRASS and MTC images, signal intensity of the superficial layer of cartilage is not a reliable sign for surface integrity.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 37 条
  • [1] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [2] BLACKBURN WD, 1994, J RHEUMATOL, V21, P675
  • [3] SEVERITY OF ARTICULAR-CARTILAGE ABNORMALITY IN PATIENTS WITH OSTEOARTHRITIS - EVALUATION WITH FAST SPIN-ECHO MR VS ARTHROSCOPY
    BRODERICK, LS
    TURNER, DA
    RENFREW, DL
    SCHNITZER, TJ
    HUFF, JP
    HARRIS, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 99 - 103
  • [4] BROWN TR, 1993, SKELETAL RADIOL, V22, P325
  • [5] KNEE HYALINE CARTILAGE EVALUATED WITH MR IMAGING - A CADAVERIC STUDY INVOLVING MULTIPLE IMAGING SEQUENCES AND INTRAARTICULAR INJECTION OF GADOLINIUM AND SALINE SOLUTION
    CHANDNANI, VP
    HO, C
    CHU, P
    TRUDELL, D
    RESNICK, D
    [J]. RADIOLOGY, 1991, 178 (02) : 557 - 561
  • [6] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [7] Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy
    Disler, DG
    McCauley, TR
    Kelman, CG
    Fuchs, MD
    Ratner, LM
    Wirth, CR
    Hospodar, PP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 127 - 132
  • [8] Hyaline cartilage: Truncation artifact as a cause of trilaminar appearance with fat-suppressed three-dimensional spoiled gradient-recalled sequences
    Erickson, SJ
    Waldschmidt, JG
    Czervionke, LF
    Prost, RW
    [J]. RADIOLOGY, 1996, 201 (01) : 260 - 264
  • [9] Frank L, 1996, RADIOLOGY, V201, P901
  • [10] MR imaging truncation artifacts can create a false laminar appearance in cartilage
    Frank, LR
    Brossmann, J
    Buxton, RB
    Resnick, D
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) : 547 - 554