Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study

被引:99
作者
Dervin, GF
Downing, KJW
Keene, GCR
McBride, DG
机构
[1] ROYAL ADELAIDE HOSP,DEPT ORTHOPAED SURG,ADELAIDE,SA 5000,AUSTRALIA
[2] SPORTSMED SA,ORTHOPAED DIV,ADELAIDE,SA,AUSTRALIA
[3] HAMPSHIRE ORTHOPAED,NORTHAMPTON,MA
来源
ARTHROSCOPY | 1997年 / 13卷 / 03期
关键词
meniscus physiology; meniscus surgery; biodegradable implants; biomechanics; polylactic acid;
D O I
10.1016/S0749-8063(97)90024-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Advances in our understanding of meniscal function and consequences of menisectomy have spawned meniscal repair techniques that yield success rates approaching 90% in properly selected patients. Biodegradable implants have been fashioned for meniscal fixation to simplify the technique and minimize neurovascular complications. We performed the current study to determine the in vitro biomechanical behavior of the BIOFIX Meniscal Arrow, a polylactic acid tack developed for meniscal repair, Eight pairs of menisci were harvested from cadaveric knees kept frozen before testing. Peripheral vertical tears were created in the posterior horn of all menisci, and each was subsequently repaired using a vertical loop suture of 2-0 Ethibond and a Meniscal arrow. Ultimate load to failure of each method was determined on a Hounsfield H25KM Universal Testing machine. The mean failure load for the suture group was 58.3 N compared with the Arrow group mean of 29.6 N (P <.001). All sutures failed by rupture at the knot but did not pull through the meniscus. All but one of the arrows failed by pulling out of the meniscus. The Arrows also permitted gapping at the repair site at considerably lesser loads than the sutures subject to strain. The concept of a biodegradable tack is appealing. Vertical loop sutures should be the standard by which their biomechanical performance is judged. We suggest modifications to the Arrow design that could enhance the fixation strength of this implant.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 20 条
[1]   Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[2]   ARTHROSCOPIC EVALUATION OF MENISCAL REPAIRS AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION AND IMMEDIATE MOTION [J].
BUSECK, MS ;
NOYES, FR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (05) :489-494
[3]  
COOPER DE, 1990, CLIN SPORT MED, V9, P589
[4]  
DEHAVEN KE, 1990, CLIN SPORT MED, V9, P577
[5]  
FAIRBANK TJ, 1948, J BONE JOINT SURG BR, V30, P644
[6]  
HENNING CE, 1990, CLIN SPORT MED, V9, P567
[7]  
HENNING CE, 1990, CLIN ORTHOP RELAT R, V252, P64
[8]  
JONES RS, UNPUB DIRECT MEASURE
[9]  
JURIST K A, 1989, Arthroscopy, V5, P141, DOI 10.1016/0749-8063(89)90010-8
[10]   THE NATURAL-HISTORY OF MENISCAL TEARS IN ANTERIOR CRUCIATE LIGAMENT INSUFFICIENCY [J].
KEENE, GCR ;
BICKERSTAFF, D ;
RAE, PJ ;
PATERSON, RS .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (05) :672-679