Multislice interleaved excitation cycles (MUSIC): An efficient gradient-echo technique for functional MRI

被引:35
作者
Loenneker, T [1 ]
Hennel, F [1 ]
Hennig, J [1 ]
机构
[1] CTR HOSP,ROUFFACH,FRANCE
关键词
magnetic resonance imaging; functional imaging; cortical activation; photic stimulation;
D O I
10.1002/mrm.1910350613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method providing improved slice efficiency for gradient-echo imaging requiring long echo times, such as in functional neuromagnetic resonance imaging, is presented. To enhance the volume coverage while maintaining the short imaging time of a conventional single-slice gradient-echo technique, an interleaved multislice excitation is performed during the echo time, This technique allows detection of susceptibility changes, e.g., the acquisition of stimulated human cortical activation maps, on clinical MR instruments at multiple planes within total imaging times of a few seconds, The efficiency of the technique is demonstrated in the detection of temporary changes in T-2* in functional MRI experiments of the human visual cortex at magnetic field strengths of 2 Tesla and 3 Tesla. Fourteen 128 x 128 slices can be acquired in 13 s to cover a large volume-of-interest in the same time that would be required for single-slice acquisition using the conventional technique.
引用
收藏
页码:870 / 874
页数:5
相关论文
共 22 条
  • [1] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [2] FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR
    BELLIVEAU, JW
    ROSEN, BR
    KANTOR, HL
    RZEDZIAN, RR
    KENNEDY, DN
    MCKINSTRY, RC
    VEVEA, JM
    COHEN, MS
    PYKETT, IL
    BRADY, TJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) : 538 - 546
  • [3] TE INTERLEAVING - NEW MULTISECTION IMAGING TECHNIQUE
    BISHOP, JE
    PLEWES, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) : 531 - 538
  • [4] FOCAL PHYSIOLOGICAL UNCOUPLING OF CEREBRAL BLOOD-FLOW AND OXIDATIVE-METABOLISM DURING SOMATOSENSORY STIMULATION IN HUMAN-SUBJECTS
    FOX, PT
    RAICHLE, ME
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (04) : 1140 - 1144
  • [5] FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) : 139 - 144
  • [6] HAASE A, 1986, J MAGN RESON, V67, P257
  • [7] DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION
    KWONG, KK
    BELLIVEAU, JW
    CHESLER, DA
    GOLDBERG, IE
    WEISSKOFF, RM
    PONCELET, BP
    KENNEDY, DN
    HOPPEL, BE
    COHEN, MS
    TURNER, R
    CHENG, HM
    BRADY, TJ
    ROSEN, BR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) : 5675 - 5679
  • [8] FAST ECHO-SHIFTED GRADIENT-RECALLED MRI - COMBINING A SHORT REPETITION TIME WITH VARIABLE T(2)ASTERISK WEIGHTING
    LIU, GY
    SOBERING, G
    OLSON, AW
    VANGELDEREN, P
    MOONEN, CTW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 68 - 75
  • [9] A FUNCTIONAL MRI TECHNIQUE COMBINING PRINCIPLES OF ECHO-SHIFTING WITH A TRAIN OF OBSERVATIONS (PRESTO)
    LIU, GY
    SOBERING, G
    DUYN, J
    MOONEN, CTW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) : 764 - 768
  • [10] LOENNEKER T, 1994, P INDIAN AS-CHEM SCI, V106, P1605