Magnetic source imaging versus intracranial electroencephalogram in epilepsy surgery: A prospective study

被引:125
作者
Knowlton, RC
Elgavish, R
Howell, J
Blount, J
Burneo, JG
Faught, E
Kankirawatana, P
Riley, K
Morawetz, R
Worthington, J
Kuzniecky, RI
机构
[1] Univ Alabama, UAB Epilepsy Ctr, Dept Neurol, Sch Med, Birmingham, AL 35294 USA
[2] Univ Alabama, Div Neurosurg, Dept Surg, Sch Med, Birmingham, AL 35294 USA
[3] Univ Western Ontario, Epilepsy Programme, Dept Clin Neurol Sci, London, ON, Canada
[4] Univ Alabama, Dept Pediat, Div Pediat Neurol, Birmingham, AL USA
[5] Univ Alabama, UAB Sch Biostat, Birmingham, AL USA
[6] NYU, Sch Med, NYU Comprehens Epilepsy Ctr, New York, NY USA
关键词
D O I
10.1002/ana.20857
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Noninvasive brain imaging tests can potentially supplement or even replace the use of intracranial electroencephalogram (ICEEG), an invasive, costly procedure used in presurgical epilepsy evaluation. This study prospectively examined the agreement between magnetic source imaging (MSI) and ICEEG localization in epilepsy surgery candidates. Methods: Patients completing video monitoring with scalp EEG who had intractable partial epilepsy based on ictal electro-clinico-anatomical features were screened. Forty-nine enrolled patients (mean age, 27 years; range, 1-61 years) completed MSI and ICEEG studies. Decisions about ICEEG and surgery were made at a consensus conference where MSI could only influence ICEEG coverage by indicating supplemental coverage to that already planned by an original hypothesis. Results: The positive predictive value of MSI for seizure localization was 82 to 90%, depending on whether computed against ICEEG alone or in combination with surgical outcome. The kappa score of agreement for MSI with ICEEG was 0.2744 (p < 0.01). Interpretation: MSI yields localizing information with a high positive predictive value in epilepsy surgery candidates who typically require ICEEG. This finding suggests that enough clinical validity exists for MSI to potentially replace ICEEG for seizure localization.
引用
收藏
页码:835 / 842
页数:8
相关论文
共 31 条
[1]   Neuromagnetic recordings in temporal lobe epilepsy [J].
Baumgartner, C ;
Pataraia, E ;
Lindinger, G ;
Deecke, L .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2000, 17 (02) :177-189
[2]   Language laterality determined by MEG mapping with MR-FOCUSS [J].
Bowyer, SM ;
Moran, JE ;
Weiland, J ;
Mason, KM ;
Greenwald, ML ;
Smith, BJ ;
Barkley, GL ;
Tepley, N .
EPILEPSY & BEHAVIOR, 2005, 6 (02) :235-241
[3]   MEG localization of language-specific cortex utilizing MR-FOCUSS [J].
Bowyer, SM ;
Moran, JE ;
Mason, KM ;
Constantinou, JE ;
Smith, BJ ;
Barkley, GL ;
Tepley, N .
NEUROLOGY, 2004, 62 (12) :2247-2255
[4]   Mapping of expressive, language cortex using magnetic source imaging [J].
Castillo, EM ;
Simos, PG ;
Venkataraman, V ;
Breier, JI ;
Wheless, JW ;
Papanicolaou, AC .
NEUROCASE, 2001, 7 (05) :419-422
[5]  
Ebersole J, 1995, STUD APPL ELECTROMAG, V7, P20
[6]   Ictal magnetic source imaging as a localizing tool in partial epilepsy [J].
Eliashiv, DS ;
Elsas, SM ;
Squires, K ;
Fried, I ;
Engel, J .
NEUROLOGY, 2002, 59 (10) :1600-1610
[7]   Current concepts - Surgery for seizures [J].
Engel, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (10) :647-652
[8]   Cortical dysplastic lesions in children with intractable epilepsy: role of complete resection [J].
Hader, WJ ;
Mackay, M ;
Otsubo, H ;
Chitoku, S ;
Weiss, S ;
Becker, L ;
Snead, OC ;
Rutka, JT .
JOURNAL OF NEUROSURGERY, 2004, 100 (02) :110-117
[9]   Surgical implications of neuromagnetic spike localization in temporal lobe epilepsy [J].
Iwasaki, M ;
Nakasato, N ;
Shamoto, H ;
Nagamatsu, K ;
Kanno, A ;
Hatanaka, K ;
Yoshimoto, T .
EPILEPSIA, 2002, 43 (04) :415-424
[10]   Magnetoencephalography in partial epilepsy: Clinical yield and localization accuracy [J].
Knowlton, RC ;
Laxer, KD ;
Aminoff, MJ ;
Roberts, TPL ;
Wong, STC ;
Rowley, HA .
ANNALS OF NEUROLOGY, 1997, 42 (04) :622-631