Patterns of in-stent restenosis after placement of NIR gold-coated stents in unselected patients

被引:11
作者
Danzi, GB
Capuano, C
Sesana, M
Di Blasi, A
Predolini, S
Antoniucci, D
机构
[1] Poliambulanza Hosp, Catheterizat Lab, Brescia, Italy
[2] Careggi Hosp, Dept Cardiol, Florence, Italy
关键词
stents; restenosis; angiography;
D O I
10.1002/ccd.10119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the incidence and angiographic patterns of in-stent restenosis 6 months after the implantation of NIR gold-coated stents in an unselected patient population. One hundred and sixteen consecutive patients were treated with the implantation of 149 NIR gold-coated stents. The majority of the patients (52%) had unstable angina or acute myocardial infarction. The baseline lesion morphology was complex in 78% of cases; the mean lesion length was 18 +/- 5 mm. The procedural success rate was 97%. Subacute stent thrombosis occurred in three patients (2.6%). During the 6-month follow-up, there were 2 deaths and 22 subjects (19.5%) underwent target vessel revascularization. The 6-month event-free survival was 60%. The angiographic restenosis rate was 32%. In 83% of the cases, the morphology of the restenosis was proliferative; in the remaining 17%, it presented as total occlusion. In conclusion, the restenosis rate after NIR gold-coated stent implantation in high-risk patients is similar to that reported using other stent designs. However, restenosis was always diffuse, involving the overall stent length and extending beyond the margins, thus indicating a greater proliferative neointimal response to this device. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 25 条
[1]  
Amant C, 1997, CIRCULATION, V96, P56
[2]  
Cremonesi A, 2000, J INVASIVE CARDIOL, V12, P225
[3]   Which variable of stenosis severity best describes the significance of an isolated left anterior descending coronary artery lesion? Correlation between quantitative coronary angiography, intracoronary Doppler measurements and high dose dipyridamole echocardiography [J].
Danzi, GB ;
Pirelli, S ;
Muri, L ;
Testa, R ;
Ciliberto, GR ;
Massa, D ;
Lotto, AA ;
Campolo, L ;
Parodi, O .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :526-533
[4]  
Danzi GB, 2001, CATHETER CARDIO INTE, V52, P147, DOI 10.1002/1522-726X(200102)52:2<147::AID-CCD1038>3.0.CO
[5]  
2-B
[6]  
Edelman ER, 2001, CIRCULATION, V103, P429
[7]   Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Pache, J ;
Wehinger, A ;
Hadamitzky, M ;
Dirschinger, J ;
Neumann, FJ ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1866-1873
[8]  
Fischell TA, 2000, J INVASIVE CARDIOL, V12, P233
[9]   Stent coatings and local drug delivery - state of the art [J].
Gunn, J ;
Cumberland, D .
EUROPEAN HEART JOURNAL, 1999, 20 (23) :1693-1700
[10]  
HEHRLEIN C, 1995, CORONARY ARTERY DIS, V6, P581