Reagentless amperometric biosensors highly sensitive to hydrogen peroxide, glucose and lactose based on N-methyl phenazine methosulfate incorporated in a Nafion film as an electron transfer mediator between horseradish peroxidase and an electrode

被引:47
作者
Liu, HY [1 ]
Ying, TL [1 ]
Sun, K [1 ]
Li, HH [1 ]
Qi, DY [1 ]
机构
[1] WEIMEI COOPERAT HANGZHOU,CLIN DEPT,HANGZHOU 310000,PEOPLES R CHINA
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
biosensors; nafion; N-methyl phenazine methosulfate; horseradish peroxidase; hydrogen peroxide; glucose oxidase; beta-galactosidase; glucose; lactose;
D O I
10.1016/S0003-2670(97)00047-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reagentless biosensors highly sensitive to hydrogen peroxide, glucose and lactose have been developed by immobilizing horseradish peroxidase (HRP), glucose oxidase (GOD) and beta-galactosidase (GAL) on Nafion-N-methyl phenazine methosulfate modified electrode. The cationic exchange of a perfluorosulfonic acid cation-exchange polymer (Nafion) film coated on a glassy carbon electrode was used to provide high local concentrations of the N-methyl phenazine ion in the Nafion film via a process of ion exchange from the solution. The incorporated N-methyl phenazine ions displayed an electrochemical behavior different from that in aqueous solution. Cyclic voltammetry and chronamperometry were employed to demonstrate the suitability of electron transfer between immobilized HRP and a glassy carbon electrode via N-methyl phenazine methosulfate (NMP) in a Nafion film. A hydrogen peroxide biosensor, prepared by immobilization of HRP alone, provided a detection limit of 75 nM. Comparison of the NMP-mediated biosensor to the mediatorless biosensor indicated that the high sensitivity of the biosensor to hydrogen peroxide arose from the high efficiency of bioelectrocatalytic reduction of hydrogen peroxide via NMP incorporated in the Nafion film. Coimmobilization of HRP and GOD was employed to establish the feasibility of highly effective bienzyme-based biosensors for low glucose concentrations. Addition of GAL to the glucose biosensor provided a sensitive response to lactose, which illustrated the suitability of trienzyme-based biosensors. Performance and characteristics of the biosensors were evaluated with respect to response time, detection limit, selectivity, and dependence on applied potential, thickness of the Nafion film, temperature and pH as well as operating and storage stability.
引用
收藏
页码:187 / 199
页数:13
相关论文
共 39 条
[1]   ELECTROCHEMISTRY IN HYDROPHOBIC NAFION GELS .1. ELECTROCHEMICAL-BEHAVIOR OF ELECTRODES MODIFIED BY HYDROPHOBIC NAFION GELS LOADED WITH FERROCENES [J].
ANDRIEUX, CP ;
AUDEBERT, P ;
DIVISIABLOHORN, B ;
ALDEBERT, P ;
MICHALAK, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 296 (01) :117-128
[2]   ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE AT A STATIONARY PYROLYTIC-GRAPHITE ELECTRODE SURFACE IN THE PRESENCE OF CYTOCHROME-C PEROXIDASE - A DESCRIPTION BASED ON A MICROELECTRODE ARRAY MODEL FOR ADSORBED ENZYME MOLECULES [J].
ARMSTRONG, FA ;
BOND, AM ;
BUCHI, FN ;
HAMNETT, A ;
HILL, HAO ;
LANNON, AM ;
LETTINGTON, OC ;
ZOSKI, CG .
ANALYST, 1993, 118 (08) :973-978
[3]   ELECTROCHEMICAL-BEHAVIOR OF NAFION GELS LOADED WITH FERROCENE AND COPPER(I) DIPHENYLPHENANTHROLINE COMPLEXES [J].
AUDEBERT, P ;
DIVISIABLOHORN, B ;
KERN, JM ;
ALDEBERT, P .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1989, (14) :939-941
[4]   TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE [J].
BIFULCO, L ;
CAMMAROTO, C ;
NEWMAN, JD ;
TURNER, APF .
ANALYTICAL LETTERS, 1994, 27 (08) :1443-1452
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   MEDIATED ELECTROCHEMICAL REDUCTION OF CYTOCHROME-C AND TYROSINASE AT PERFLUOROSULFONATED IONOMER COATED ELECTRODES [J].
FURBEE, JW ;
THOMAS, CR ;
KELLY, RS ;
MALACHOWSKI, MR .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1654-1657
[7]   ELECTRODES MODIFIED WITH NAFION FILMS INCORPORATING AMPHIPHILIC FERROCENE DERIVATIVES [J].
GARCIA, O ;
KAIFER, AE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 279 (1-2) :79-94
[8]  
Gierke T. D., 1982, PERFLUORINATED IONOM, V180
[9]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[10]   AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDIZING ENZYMES AND CHEMICALLY MODIFIED ELECTRODES [J].
GORTON, L ;
BREMLE, G ;
CSOREGI, E ;
JONSSONPETTERSSON, G ;
PERSSON, B .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :43-54