Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode

被引:237
作者
Inoue, T [1 ]
Kirchhoff, JR [1 ]
机构
[1] Univ Toledo, Dept Chem, Toledo, OH 43606 USA
关键词
D O I
10.1021/ac0108515
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemically modified electrode has been developed as a detector for the sensitive and selective determination of thiol-containing compounds following capillary electrophoresis separation. Electrodes were constructed by entrapment of the coenzyme pyrroloquinoline quinone (PQQ) into a polypyrrole (PPy) matrix on a 245-mum graphite electrode during electropolymerization of pyrrole in the presence of PQQ. PQQ serves as an efficient biocatalyst to mediate the oxidation of thiols at a substantially reduced overpotential relative to an unmodified electrode. Furthermore, this design takes advantage of the pH-dependent reversible electrochemical properties of PQQ, which facilitates optimization of separation and detection conditions. The PQQ/PPy-modified electrode was incorporated as an end-column detector, and a separation of homocysteine, cysteine, N-acetylcysteine, and glutathione was developed. Detection limits for these four thiols were determined to be 11, 23, 104, and 134 nM, respectively, with mass detection limits ranging from 0.29 to 3.48 fmol. The PQQ/PPy electrode was also found to be very reproducible in run-to-run, day-to-day, and electrode-to-electrode comparisons. The utility of this electrode was demonstrated for the detection of cysteine in dietary supplements and human urine, resulting in excellent agreement with reported values.
引用
收藏
页码:1349 / 1354
页数:6
相关论文
共 35 条
[1]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[2]  
Baldwin RP, 2000, ELECTROPHORESIS, V21, P4017, DOI 10.1002/1522-2683(200012)21:18<4017::AID-ELPS4017>3.3.CO
[3]  
2-X
[4]  
BERGSTROM RF, 1978, ANAL CHEM, V50, P2108
[5]   THE CONCENTRATIONS OF CYSTEINE AND CYSTINE IN HUMAN BLOOD PLASMA [J].
BRIGHAM, MP ;
STEIN, WH ;
MOORE, S .
JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (11) :1633-1638
[6]   THIOL AND DISULFIDE DETERMINATION BY FREE ZONE CAPILLARY ELECTROPHORESIS [J].
CAPPIELLO, M ;
DELCORSO, A ;
CAMICI, M ;
MURA, U .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1993, 26 (04) :335-341
[7]  
Cox JA, 1996, REV ANAL CHEM, V15, P173
[8]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF INSULIN BASED UPON ITS OXIDATION AT A MODIFIED ELECTRODE [J].
COX, JA ;
GRAY, TJ .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2462-2464
[9]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[10]  
Foret F., 1993, CAPILLARY ZONE ELECT