Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli

被引:127
作者
Moehring, MA
Spencer, MP
机构
[1] Spencer Technol, Seattle, WA 98122 USA
[2] Spencer Vasc Labs, Seattle, WA USA
关键词
transcranial Doppler; M-mode; embolism; ultrasound; microemboli;
D O I
10.1016/S0301-5629(01)00486-0
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Difficulties in location of transcranial ultrasound (US) windows and blood flow in cerebral vessels, and unambiguous detection of microemboli, have limited expansion of transcranial Doppler US. We developed a new transcranial Doppler modality, power M-mode Doppler (PMD), for addressing these issues. A 2-MHz digital Doppler (Spencer Technologies TCD100M) having 33 sample gates placed with 2-mm spacing was configured to display Doppler signal power, colored red and blue for directionality, in an M-mode format. The spectrogram from a user-selected depth was displayed simultaneously. This system was then explored on healthy subjects and patients presenting with varying cerebrovascular pathology. PMD facilitated window location and alignment of the US beam to view blood flow from multiple vessels simultaneously, without sound or spectral clues. Microemboli appeared as characteristic sloping high-power tracks in the PMD image. Power M-mode Doppler Is a new paradigm facilitating vessel location, diagnosis, monitoring and microembolus detection. (E-mail: mm@spencertechnologies.com) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 16 条
[1]   Association of intraoperative transcranial Doppler monitoring variables with stroke from carotid endarterectomy [J].
Ackerstaff, RGA ;
Moons, KGM ;
van de Vlasakker, CJW ;
Moll, FL ;
Vermeulen, FEE ;
Algra, A ;
Spencer, MP .
STROKE, 2000, 31 (08) :1817-1823
[2]   Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts [J].
Cullinane, M ;
Reid, G ;
Dittrich, R ;
Kaposzta, Z ;
Ackerstaff, R ;
Babikian, V ;
Droste, DW ;
Grossett, D ;
Siebler, M ;
Valton, L ;
Markus, HS .
STROKE, 2000, 31 (06) :1335-1341
[3]   COLOR DIGITAL ECHO-DOPPLER IMAGE PRESENTATION [J].
EYER, MK ;
BRANDESTINI, MA ;
PHILLIPS, DJ ;
BAKER, DW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (01) :21-&
[4]  
ISHII M, 1999, STROKE, V30, P863
[5]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[6]   PULSE DOPPLER ULTRASOUND DETECTION, CHARACTERIZATION AND SIZE ESTIMATION OF EMBOLI IN FLOWING BLOOD [J].
MOEHRING, MA ;
KLEPPER, JR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (01) :35-44
[7]  
MOEHRING MA, 2001, CEREBROVASC DIS, V11, P4
[8]  
MOEHRING MA, 2000, CEREBROVASC DIS, V10, P2
[9]   Detection of microembolic signals in patients with middle cerebral artery stenosis by means of a bigate probe - A pilot study [J].
Nabavi, DG ;
Georgiadis, D ;
Mumme, T ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (08) :1347-1349
[10]  
OMOTO R, 1984, JPN HEART J, V25, P325