Assessment of single motor unit conduction velocity during sustained contractions of the tibialis anterior muscle with advanced spike triggered averaging

被引:99
作者
Farina, D
Arendt-Nielsen, L
Merletti, R
Graven-Nielsen, T [1 ]
机构
[1] Politecn Torino, Ctr Bioing, Dept Elect, Turin, Italy
[2] Univ Aalborg, Ctr Sensor Motor Interact, Lab Expt Pain Res, DK-9220 Aalborg, Denmark
关键词
surface electromyography; intramuscular electromyography; rate coding; single motor unit conduction velocity; fatigue; spike triggered averaging; maximum likelihood delay estimators;
D O I
10.1016/S0165-0270(01)00510-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an improved spike triggered averaging technique for the assessment of control properties and conduction velocity (CV) of single motor units (MUs) of the tibialis anterior muscle during voluntary muscle contractions. The method is based on the detection of multi-channel surface EMG signals (with linear electrode arrays) and intramuscularly recorded single MU action potentials (MUAPs). Intramuscular electrodes were inserted in the muscle taking into account the MU structural properties (innervation zone, tendon locations, length of the fibers), assessed by the linear array surface EMG detection technique. An algorithm for intramuscular EMG signal decomposition is used to identify single MUAP trains. The MUAPs detected by the intramuscular EMG decomposition algorithm were used to trigger and average the multi-channel EMG signals. CV of single averaged surface MUAPs was estimated by the use of advanced signal processing methods based on multi-channel recordings which allow to consistently reduce the variance of CV estimates compared with traditional two channel delay estimators. The number of averaged potentials can thus be limited, resulting in high temporal resolution CV estimates. The developed technique was tested on recordings from the tibialis anterior muscle in 11 volunteers during fatigue. It was shown that the method allows the assessment of single MU CV changes (fatigue) as small as 0.1 m/s with less than 2 s data epochs. The method allows reliable assessment of firing rate and conduction properties of single MUs with applications for the investigation of central and peripheral fatigue mechanisms. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 37 条
[1]   MUSCLE-FIBER CONDUCTION-VELOCITY IN MOTOR UNITS OF THE HUMAN ANTERIOR TIBIAL MUSCLE - A NEW SIZE PRINCIPLE PARAMETER [J].
ANDREASSEN, S ;
ARENDTNIELSEN, L .
JOURNAL OF PHYSIOLOGY-LONDON, 1987, 391 :561-571
[2]  
Arendt-Nielsen L., 1984, J PHYSL, V353, p6P
[3]   MEASUREMENT OF MUSCLE-FIBER CONDUCTION-VELOCITY IN HUMANS - TECHNIQUES AND APPLICATIONS [J].
ARENDTNIELSEN, L ;
ZWARTS, M .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1989, 6 (02) :173-190
[4]  
BERGAMO R, 1999, P S MUSC DIS COMP US, P198
[5]   A NOTE ON THE NONINVASIVE ESTIMATION OF MUSCLE-FIBER CONDUCTION-VELOCITY [J].
BROMAN, H ;
BILOTTO, G ;
DE LUCA, CJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (05) :341-344
[6]   LIMITATIONS OF THE SPIKE-TRIGGERED AVERAGING TECHNIQUE [J].
CALANCIE, B ;
BAWA, P .
MUSCLE & NERVE, 1986, 9 (01) :78-83
[7]   Motor unit control properties in constant-force isometric contractions [J].
De Luca, CJ ;
Foley, PJ ;
Erim, Z .
JOURNAL OF NEUROPHYSIOLOGY, 1996, 76 (03) :1503-1516
[8]   Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays [J].
Farina, D ;
Fortunato, E ;
Merletti, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (03) :380-388
[9]   Concentric-ring electrode systems for noninvasive detection of single motor unit activity [J].
Farina, D ;
Cescon, C .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (11) :1326-1334
[10]   Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays [J].
Farina, D ;
Muhammad, W ;
Fortunato, E ;
Meste, O ;
Merletti, R ;
Rix, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (02) :225-236