PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine

被引:98
作者
Amini, MK [1 ]
Shahrokhian, S [1 ]
Tangestaninejad, S [1 ]
机构
[1] Univ Esfahan, Dept Chem, Esfahan 81744, Iran
关键词
D O I
10.1021/ac9812633
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, performance characteristics, and application of a polymeric membrane coated on a graphite electrode with unique selectivity toward histidine are reported. The electrode was prepared by incorporating chloro(5,10,15,20-tetraphenylporphyrinato) manganese(III) [Mn(TPP)Cl] into a plasticized poly(vinyl chloride) membrane. The influences of membrane composition, pH, and foreign ions were investigated. Calibration plots with near Nernstian slopes for histidine were observed, -55.4 mV/decade, over a linear range of four decades of concentration (1 x 10(-5) to 1 x 10(-1) M). The electrode has a detection limit of 5 x 10(-6) M histidine and shows a fast response time of about 1 min. The electrode shows high selectivities toward histidine over several amino acids and common inorganic anions.
引用
收藏
页码:2502 / 2505
页数:4
相关论文
共 31 条
  • [1] HYDROXIDE ION-SELECTIVE POLYMERIC MEMBRANE-COATED WIRE ELECTRODE BASED ON OXOMOLYBDENUM(V) TETRAPHENYLPORPHYRIN COMPLEX
    ABE, H
    KOKUFUTA, E
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1990, 63 (05) : 1360 - 1364
  • [2] ANION SELECTIVITY OF METALLOPORPHYRINS IN MEMBRANES
    AMMANN, D
    HUSER, M
    KRAUTLER, B
    RUSTERHOLZ, B
    SCHULTHESS, P
    LINDEMANN, B
    HALDER, E
    SIMON, W
    [J]. HELVETICA CHIMICA ACTA, 1986, 69 (04) : 849 - 854
  • [3] POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX
    BADR, IHA
    MEYERHOFF, ME
    HASSAN, SSM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2613 - 2618
  • [4] ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY
    BAKKER, E
    MALINOWSKA, E
    SCHILLER, RD
    MEYERHOFF, ME
    [J]. TALANTA, 1994, 41 (06) : 881 - 890
  • [5] BELLI SL, 1986, ANAL LETT, V19, P403
  • [6] INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES
    CHANIOTAKIS, NA
    CHASSER, AM
    MEYERHOFF, ME
    GROVES, JT
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (02) : 185 - 188
  • [7] SALICYLATE-SELECTIVE MEMBRANE-ELECTRODE BASED ON TIN(IV) TETRAPHENYLPORPHYRIN
    CHANIOTAKIS, NA
    PARK, SB
    MEYERHOFF, ME
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (06) : 566 - 570
  • [8] POTENTIOMETRIC PHOSPHATE SELECTIVE ELECTRODE BASED ON A MULTIDENDATE TIN(IV) CARRIER
    CHANIOTAKIS, NA
    JURKSCHAT, K
    RUHLEMANN, A
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 345 - 352
  • [9] ANION-SELECTIVE ELECTRODES BASED ON ELECTROPOLYMERIZED PORPHYRIN FILMS
    DAUNERT, S
    WALLACE, S
    FLORIDO, A
    BACHAS, LG
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1676 - 1679
  • [10] Porphyrin-modified electrodes as biomimetic sensors for the determination of organohalide pollutants in aqueous samples
    Dobson, DJ
    Saini, S
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3532 - 3538