Petrosal bone: Coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans

被引:36
作者
Venema, HW
Phoa, SSKS
Mirck, PGB
Hulsmans, FJH
Majoie, CBLM
Verbeeten, B
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Otorhinolaryngol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Med Phys, NL-1105 AZ Amsterdam, Netherlands
关键词
computed tomography (CT); image processing; thin section; temporal bone; CT;
D O I
10.1148/radiology.213.2.r99nv11375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate whether coronal multiplanar reconstruction (MPR) images of the petrosal bone from axial spiral computed tomographic (CT) data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans obtained with 0.5- or 1.0-mm collimation. MATERIALS AND METHODS: The differences in diagnostic quality between thin-section coronal sequential CT scans of 24 petrosal bones in 12 patients and matched MPR images were assessed by five observers. The matched MPR images were calculated with both trilinear and tricubic interpolation. Image resolution was determined by measuring the three-dimensional point spread function. RESULTS: All observers preferred tricubically interpolated MPR images over trilinearly interpolated images. Subjective differences in image quality between direct coronal scans and matched tricubically interpolated MPR images were small. Only the direct coronal scans with the highest image quality (0.5-mm collimation, 465 mAs) were judged to be slightly better than the matched MPR images. With regard to direct coronal scans obtained at 245 mAs and/or 1.0-mm collimation, either there was no preference or the MPR images were preferred. CONCLUSION: Coronal MPR images from axial spiral CT obtained with 0.5-mm collimation can replace direct coronal sequential CT scans.
引用
收藏
页码:375 / 382
页数:8
相关论文
共 21 条
[1]  
ABRAMOWITZ M, 1970, HDB MATH FUNCTIONS, P879
[2]  
Barrow Harry G., 1977, P IMAGE UNDERSTANDIN
[3]   CT scanning of the paranasal sinuses:: axial helical CT with reconstruction in the coronal direction versus coronal helical CT [J].
Bernhardt, TM ;
Rapp-Bernhardt, U ;
Fessel, A ;
Ludwig, K ;
Reichel, G ;
Grote, R .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848) :846-851
[4]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[5]  
CALDEMEYER KS, 1997, RADIOLOGY S, V205, P362
[6]   A REGISTRATION AND INTERPOLATION PROCEDURE FOR SUBVOXEL MATCHING OF SERIALLY ACQUIRED MR-IMAGES [J].
HAJNAL, JV ;
SAEED, N ;
SOAR, EJ ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (02) :289-296
[7]  
HERMANS R, 1995, NEURORADIOLOGY, V37, P150
[8]   THIN-SECTION 3-DIMENSIONAL SPIRAL CT - IS ISOTROPIC IMAGING POSSIBLE [J].
KALENDER, WA .
RADIOLOGY, 1995, 197 (03) :578-580
[9]   Normal and opacified middle ears: CT appearance of the stapes and incudostapedial joint [J].
Lemmerling, MM ;
Stambuk, HE ;
Mancuso, AA ;
Antonelli, PJ ;
Kubilis, PS .
RADIOLOGY, 1997, 203 (01) :251-256
[10]   Dual-slice spiral versus single-slice spiral scanning: Comparison of the physical performance of two computed tomography scanners [J].
Liang, Y ;
Kruger, RA .
MEDICAL PHYSICS, 1996, 23 (02) :205-220