Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators

被引:105
作者
Brigadeau, F [1 ]
Kouakam, C
Klug, D
Marquié, C
Duhamel, A
Mizon-Gérard, F
Lacroix, D
Kacet, S
机构
[1] CHRU, Hop Cardiol Lille, Dept Cardiol A, F-59037 Lille, France
[2] Lille Univ Hosp, Dept Biostat, Lille, France
关键词
electrical storm; ICD; ventricular arrhythmias; diabetes; dyslipidaemia; chronic renal failure;
D O I
10.1093/eurheartj/ehi726
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Insufficient data exists regarding predictors of electrical storms (ES) and clinical outcome in patients treated with an implantable cardioverter defibrillator (ICD). The purpose of this study was to delineate a subgroup of patients likely to experience ES and to determine the impact of ES on mortality in ICD recipients. Methods and results Baseline characteristics of 307 ICD-treated patients were retrospectively analysed. ES was defined as two or more ventricular tachyarrhythmias within 24 h leading to an immediate electrical therapy (antitachycardia pacing and/or shock), separated by a period of sinus rhythm. Clinical characteristics and survival of 123 patients experiencing a total of 294 episodes of ES (median 2 ES/patient, range 1-9), were compared with those of 184 ES-free patients during a median follow-up of 826 days (inter-quartile 1141 days). Median actuarial duration for the first ES occurrence after ICD implant was 1417 days [95% confidence interval (CI) 1061-2363] with a median follow-up of 816 days (7-4642 days) in ES-free patients. Univariate analysis identified older age, depressed left ventricular ejection fraction (LVEF), ventricular tachycardia (VT) as index arrhythmia, chronic renal failure and absence of lipid-lowering drugs as variables significantly associated with an increased risk of ES. Multivariable Cox analysis confirmed an independent predictive value for chronic renal failure [hazard ratio (HR) 1.54, 95% CI 0.95-2.51, P=0.052], VT (HR 2.20, 95% CI 1.44-3.37, P=0.0003), and LVEF (HR 0.98, 95% CI 0.97-0.99, P=0.027). In contrast, diabetics (HR 0.49, 95% CI 0.27-0.90, P=0.022) were less affected by ES. There was no difference in survival between both groups. Conclusion ES is frequent but does not increase mortality in ICD's recipients. Patients with severe systolic dysfunction, chronic renal failure and VT as initial arrhythmia are likely to experience ES. Diabetics are less affected by ES.
引用
收藏
页码:700 / 707
页数:8
相关论文
共 38 条
  • [1] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) : 225 - 237
  • [2] Potential benefit from implantable cardioverter-defibrillator therapy in patients with and without heart failure
    Böcker, D
    Bänsch, D
    Heinecke, A
    Weber, M
    Brunn, J
    Hammel, D
    Borggrefe, M
    Breithardt, G
    Block, P
    [J]. CIRCULATION, 1998, 98 (16) : 1636 - 1643
  • [3] Ventricular arrhythmias following exposure of failing hearts to oxidative stress in vitro
    Brigadeau, F
    Gelé, P
    Marquié, C
    Soudan, B
    Lacroix, D
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) : 629 - 636
  • [4] A randomized study of the prevention of sudden death in patients with coronary artery disease
    Buxton, AE
    Lee, KL
    Fisher, JD
    Josephson, ME
    Prystowsky, EN
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) : 1882 - 1890
  • [5] Electrical storm in patients with transvenous implantable cardioverter-defibrillators - Incidence, management and prognostic implications
    Credner, SC
    Klingenheben, T
    Mauss, O
    Sticherling, C
    Hohnloser, SH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) : 1909 - 1915
  • [6] SUDDEN-DEATH, IMPAIRED GLUCOSE-TOLERANCE, AND DIABETES IN JAPANESE-AMERICAN MEN
    CURB, JD
    RODRIGUEZ, BL
    BURCHFIEL, CM
    ABBOTT, RD
    CHIU, D
    YANO, K
    [J]. CIRCULATION, 1995, 91 (10) : 2591 - 2595
  • [7] Lipid lowering drugs and recurrences of life-threatening ventricular arrhythmias in high-risk patients
    De Sutter, J
    Tavernier, R
    De Buyzere, M
    Jordaens, L
    De Backer, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 766 - 772
  • [8] ELECTROPHYSIOLOGICAL AND ANATOMIC DIFFERENCES BETWEEN CANINE HEARTS WITH INDUCIBLE VENTRICULAR-TACHYCARDIA AND FIBRILLATION ASSOCIATED WITH CHRONIC MYOCARDIAL-INFARCTION
    DENNISS, AR
    RICHARDS, DA
    WAYWOOD, JA
    YUNG, T
    KAM, CA
    ROSS, DL
    UTHER, JB
    [J]. CIRCULATION RESEARCH, 1989, 64 (01) : 155 - 166
  • [9] Dorian P, 1997, ARCH MAL COEUR VAISS, V90, P27