Detection limits and goodness-of-fit measures for the two-component model of chemical analytical error

被引:24
作者
Wilson, MD [1 ]
Rocke, DM
Durbin, B
Kahn, HD
机构
[1] Univ Georgia, Savannah River Ecol Lab, Aiken, SC 29802 USA
[2] Univ Calif Davis, Davis, CA 95616 USA
[3] US EPA, Washington, DC 20460 USA
关键词
chemical analytical error; limits of detection; two-component error models; goodness-of-fit;
D O I
10.1016/j.aca.2003.12.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The utility of analytical chemistry measurements in most applications is dependent on an assessment of measurement error. This paper demonstrates the use of a two-component error model in setting limits of detection and related concepts and introduces two goodness-of-fit statistics for assessing the appropriateness of the model for the data at hand. The model is applicable to analytical methods in which high concentrations are measured with approximately constant relative standard deviation. At low levels, the relative standard deviation cannot stay constant, since this implies vanishingly small absolute standard deviation. The two-component model has approximately constant standard deviation near zero concentration, and approximately constant relative standard deviation at high concentrations, a pattern that is frequently observed in practice. Here we discuss several important applications of the model to environmental monitoring and also introduce two goodness-of-fit statistics, to ascertain whether the data exhibit the error structure assumed by the model, as well as to took for problems with experimental design. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 208
页数:12
相关论文
共 17 条
[1]  
Cohen A. C., 1991, Truncated and Censored Samples: Theory and Applications
[3]   Detection: International update, and some emerging di-lemmas involving calibration, the blank, and multiple detection decisions [J].
Currie, LA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 37 (01) :151-181
[4]   NOMENCLATURE IN EVALUATION OF ANALYTICAL METHODS INCLUDING DETECTION AND QUANTIFICATION CAPABILITIES (IUPAC RECOMMENDATIONS 1995) [J].
CURRIE, LA .
PURE AND APPLIED CHEMISTRY, 1995, 67 (10) :1699-1723
[5]  
Efron B., 1994, INTRO BOOTSTRAP, DOI DOI 10.1201/9780429246593
[6]  
GIBBBONS RD, 1994, STAT METHODS GROUNDW
[7]   An alternative minimum level definition for analytical quantification [J].
Gibbons, RD ;
Coleman, DE ;
Maddalone, RF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) :2071-2077
[8]  
Gilbert R.O., 1987, RO GILBERT BIOMETRIC
[9]   Determining elemental compositions from exact masses and relative abundances of ions [J].
Grange, AH ;
Brumley, WC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (01) :12-17
[10]   DECISION AND DETECTION LIMITS FOR LINEAR CALIBRATION CURVES [J].
HUBAUX, A ;
VOS, G .
ANALYTICAL CHEMISTRY, 1970, 42 (08) :849-&