Comparison of diffusion-weighted high-resolution CBF and spin-echo BOLD fMRI at 9.4 T

被引:51
作者
Lee, SP [1 ]
Silva, AC [1 ]
Kim, SG [1 ]
机构
[1] Univ Minnesota, Sch Med, Ctr Magnet Resonance Res, Dept Radiol, Minneapolis, MN 55455 USA
关键词
functional brain mapping; BOLD; arterial spin labeling; rat brain; forepaw stimulation; high resolution; high field;
D O I
10.1002/mrm.10117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quantification of blood oxygenation-level dependent (BOLD) functional MRI (fMRI) signals is closely related to cerebral blood flow (CBF) change; therefore, understanding the exact relationship between BOLD and CBF changes on a pixel-by-pixel basis is fundamental. In this study, quantitative CBF changes induced by neural activity were used to quantify BOLD signal changes during somatosensory stimulation in alpha-chloralose-anesthetized rats. To examine the influence of fast-moving vascular spins in quantifying CBF, bipolar gradients were employed. Our data show no significant difference in relative CBF changes obtained with and without bipolar gradients. To compare BOLD and CBF signal changes induced by neural stimulation, a spin-echo (SE) sequence with long SE time of 40 ms at 9.4 T was used in conjunction with an arterial spin labeling technique. SE BOLD changes were quantitatively correlated to CBF changes on a pixel-by-pixel and animal-by-animal basis. Thus, SE BOLD-based fMRI at high magnetic fields allows a quantitative comparison of functional brain activities across brain regions and subjects. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:736 / 741
页数:6
相关论文
共 40 条
[1]   EFFECTS OF BIOPHYSICAL AND PHYSIOLOGICAL-PARAMETERS ON BRAIN ACTIVATION-INDUCED R(2)ASTERISK AND R(2) CHANGES - SIMULATIONS USING A DETERMINISTIC DIFFUSION-MODEL [J].
BANDETTINI, PA ;
WONG, EC .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) :133-152
[2]   A model for the coupling between cerebral blood flow and oxygen metabolism during neural stimulation [J].
Buxton, RB ;
Frank, LR .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (01) :64-72
[3]  
COHEN ER, 2001, P 9 ANN M ISMRM GLAS, P1190
[4]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[5]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[6]  
Duong TQ, 2000, MAGN RESON MED, V43, P383, DOI 10.1002/(SICI)1522-2594(200003)43:3<383::AID-MRM10>3.0.CO
[7]  
2-Q
[8]  
Duong TQ, 2000, MAGNET RESON MED, V43, P393, DOI 10.1002/(SICI)1522-2594(200003)43:3<393::AID-MRM11>3.0.CO
[9]  
2-K
[10]   Localized cerebral blood flow response at submillimeter columnar resolution [J].
Duong, TQ ;
Kim, DS ;
Ugurbil, K ;
Kim, SG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (19) :10904-10909