Evaluation of Monte Carlo simulation of photon counting efficiency for germanium detectors

被引:22
作者
Kamboj, S [1 ]
Kahn, B [1 ]
机构
[1] GEORGIA INST TECHNOL, SCH MECH ENGN, HLTH PHYS & NUCL ENGN PROGRAM, ATLANTA, GA 30332 USA
来源
HEALTH PHYSICS | 1996年 / 70卷 / 04期
关键词
Monte Carlo; photons; detector; germanium; counting efficiency;
D O I
10.1097/00004032-199604000-00008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The reliability of calculating the full-energy peak counting efficiency of germanium detectors by Monte Carlo simulation was evaluated by comparing MCNP-4 code results with measurements over a range of conditions, The measurements were performed for two detectors of 20% and 110% nominal efficiencies with a point source at two distances and with four different volume sources, including a reentrant beaker, placed on the end caps, The radionuclides were National Institute of Standards and Technology standard sources that emit photons between energies of 42.8 and 1,596.4 keV. Each detector was modeled in detail with respect to the dimensions of the detection volume and attenuation material in the can, dead layer, and crystal holder foil. The measurements of the 42.8-keV photon were used to check dimensions and to change slightly the value of the dead-layer thickness so that the simulation agreed with measurements at this energy, After this adjustment, the average ratio of simulation results to measurements for 13 photon energies above 42.8 keV was between 0.97 and 1.03 for all sets of point and volume source comparisons. Ratios at individual energies were between 0.92 and 1.06 for the point source and between 0.94 and 1.09 for volume sources, The observed differences were consistent with the estimated standard deviations of simulation and of measurement, which ranged from 1 to 6% and typically were 2 to 3% except for larger uncertainties at low energies, On the basis of this comparison, simulation with the MCNP-4 code is equivalent to measurement with photon standards if the detector and source configuration can be modeled within a tenth of a millimeter.
引用
收藏
页码:512 / 519
页数:8
相关论文
共 14 条
[1]   VALIDATION OF A METHOD FOR COMPUTER CALCULATION OF GERMANIUM DETECTOR EFFICIENCIES [J].
AALTONEN, H ;
KLEMOLA, S ;
UGLETVEIT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :87-91
[2]  
BRIESMEISTER JF, 1990, LA7396M LOS AL NAT L
[3]   AN INVESTIGATION OF THE POSSIBLE INTERACTION MECHANISMS FOR SI(LI) AND GE DETECTOR RESPONSE FUNCTIONS BY MONTE-CARLO SIMULATION [J].
GARDNER, RP ;
YACOUT, AM ;
ZHANG, J ;
VERGHESE, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03) :399-405
[4]   DEPENDENCE OF EFFICIENCY CURVE FOR GE(LI) DETECTORS ON DETECTOR SHAPE [J].
HNATOWICZ, V .
NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (03) :403-407
[5]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[6]  
KAMBOJ S, 1994, THESIS GEORGIA I TEC
[7]   CALCULATION OF THE ABSOLUTE PEAK EFFICIENCY OF GAMMA-RAY DETECTORS FOR DIFFERENT COUNTING GEOMETRIES [J].
MOENS, L ;
DEDONDER, J ;
LIN, X ;
DECORTE, F ;
DEWISPELAERE, A ;
SIMONITS, A ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3) :451-472
[8]   COMPARISON OF CALCULATED AND MEASURED RESPONSE FUNCTIONS FOR GERMANIUM DETECTORS [J].
MOSS, CE ;
STREETMAN, JR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3) :98-101
[9]   MONTE-CARLO CALCULATION OF PEAK EFFICIENCIES AND RESPONSE FUNCTIONS OF COAXIAL-TYPE GE(LI) DETECTORS FOR DISK GAMMA-RAY SOURCES [J].
NAKAMURA, T .
NUCLEAR INSTRUMENTS & METHODS, 1975, 131 (03) :521-527
[10]   MORE REALISTIC MONTE-CARLO CALCULATIONS OF PHOTON DETECTOR RESPONSE FUNCTIONS [J].
ROGERS, DWO .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 199 (03) :531-548