摘要
Purpose: Evaluation of high-resolution 2D-RARE MRCP in the diagnosis of pancreaticobiliary diseases. Materials and Methods: 23 patients with various pancreaticobiliary diseases were evaluated using conventional and high-resolution 2D-RARE sequences. Results: High-resolution RARE MRCP allowed for improved delineation of biliary and pancreatic ducts at the expense of reduced signal-to-noise ratio. Pathological findings were significantly (p<0.001) better demonstrated with high resolution RARE MRCP (score 1.65 +/- 0.54) as compared to the conventional RARE sequence (score 2.58+/-0.62). Conclusions: High-resolution 2D-RARE-MRCP improves the delineation of biliary and pancreatic ducts. This sequence should replace the conventional 2D-RARE sequence.
引用
收藏
页码:254 / 257
页数:4
相关论文
共 14 条
[1]   MR-CHOLANGIOPANCREATOGRAPHY - EFFICACY OF 3-DIMENSIONAL TURBO SPIN-ECHO TECHNIQUE [J].
BARISH, MA ;
YUCEL, EK ;
SOTO, JA ;
CHUTTANI, R ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :295-300
[2]   Breath-hold MR cholangiopancreatography using a HASTE sequence: Comparison of single-slice and multislice acquisition techniques [J].
Ernst, O ;
Calvo, M ;
Sergent, G ;
Mizrahi, D ;
Carpentier, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1304-1306
[3]   Half-Fourier RARE MR cholangiopancreatography: Experience in 300 subjects [J].
Fulcher, AS ;
Turner, MA ;
Capps, GW ;
Zfass, AM ;
Baker, KM .
RADIOLOGY, 1998, 207 (01) :21-32
[4]   DIAGNOSIS OF CHOLEDOCHOLITHIASIS - VALUE OF MR CHOLANGIOGRAPHY [J].
GUIBAUD, L ;
BRET, PM ;
REINHOLD, C ;
ATRI, M ;
BARKUN, ANG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :847-850
[5]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[6]   BREATH-BOLD PROJECTION MAGNETIC-RESONANCE CHOLANGIO-PANCREATICOGRAPHY (MRCP) - A NEW METHOD FOR THE EXAMINATION OF THE BILE AND PANCREATIC DUCTS [J].
LAUBENBERGER, R ;
BUCHERT, M ;
SCHNEIDER, B ;
BLUM, U ;
HENNIG, J ;
LANGER, M .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :18-23
[7]   MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences [J].
Miyazaki, T ;
Yamashita, Y ;
Tsuchigame, T ;
Yamamoto, H ;
Urata, J ;
Takahashi, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1297-1303
[8]   BILIARY OBSTRUCTION - EVALUATION WITH 3-DIMENSIONAL MR CHOLANGIOGRAPHY [J].
MORIMOTO, K ;
SHIMOI, M ;
SHIRAKAWA, T ;
AOKI, Y ;
CHOI, S ;
MIYATA, Y ;
HARA, K .
RADIOLOGY, 1992, 183 (02) :578-580
[9]   MR cholangiography in biliary obstruction using half-Fourier acquisition [J].
Regan, F ;
Smith, D ;
Khazan, R ;
Bohlman, M ;
SchultzeHaakh, H ;
Campion, J ;
Magnuson, TH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (04) :627-632
[10]   MR CHOLANGIOPANCREATOGRAPHY - COMPARISON BETWEEN 2-DIMENSIONAL FAST SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO PULSE SEQUENCES [J].
REINHOLD, C ;
GUIBAUD, L ;
GENIN, G ;
BRET, PM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :379-384