Determination of pulmonary mean transit time and cardiac output using a one-dimensional model

被引:3
作者
LeSech, C [1 ]
Capderou, A [1 ]
机构
[1] CTR CHIRURG MARIE LANNELONGUE,URA CNRS 1159,PHYSIOL LAB,F-92350 LE PLESSIS ROBINS,FRANCE
关键词
D O I
10.1016/S0092-8240(96)00042-0
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this work, we show that a one-dimensional model of the blood flow across the lungs can reproduce the evolution of a bolus versus the time. Solving the differential equation governing the bolus concentration in the framework of this model, we determine the solution which fulfills Gaussian initial boundary conditions. An effective parameter related to the ratio of a diffusion coefficient to the square of the mean speed of the flow is defined. The determination of its numerical values following a semi-empirical approach enables us to know accurately the mean transit time and the cardiac output. The results have been compared to other methods, and were found in good agreement. Such an approach could be of interest in all studies where the knowledge of flow-including micro-circulation-is needed. (C) 1996 Society for Mathematical Biology
引用
收藏
页码:1155 / 1170
页数:16
相关论文
共 23 条
[1]  
ADAMS R, 1978, J NUCL MED, V19, P538
[2]   ESTIMATION OF THE PULMONARY CAPILLARY TRANSPORT FUNCTION IN ISOLATED RABBIT LUNGS [J].
AUDI, SH ;
LINEHAN, JH ;
KRENZ, GS ;
DAWSON, CA ;
AHLF, SB ;
ROERIG, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (03) :1004-1014
[3]   APPLICATIONS OF LAGGED NORMAL DENSITY CURVE AS A MODEL FOR ARTERIAL DILUTION CURVES [J].
BASSINGT.JB ;
ACKERMAN, FH ;
WOOD, EH .
CIRCULATION RESEARCH, 1966, 18 (04) :398-&
[4]   AN EFFICIENT METHOD FOR SMOOTHING INDICATOR - DILUTION AND OTHER UNIMODAL CURVES [J].
BASSINGTHWAIGHTE, JB ;
CHAN, IS ;
GOLDSTEIN, AA .
COMPUTERS AND BIOMEDICAL RESEARCH, 1988, 21 (02) :192-202
[5]   FITTING SMOOTH CURVES TO NOISY INDICATOR-DILUTION AND OTHER UNIMODAL DATA [J].
BEYER, RP .
COMPUTERS AND BIOMEDICAL RESEARCH, 1992, 25 (02) :144-152
[6]   INFLUENCE OF PULMONARY VASOCONSTRICTION ON LUNG WATER AND PERFUSION HETEROGENEITY [J].
DAWSON, CA ;
BRONIKOWSKI, TA ;
LINEHAN, JH ;
HAKIM, TS .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (03) :654-660
[7]   RADIONUCLIDE METHODS FOR CARDIAC-OUTPUT DETERMINATION [J].
FOUADTARAZI, FM ;
MACINTYRE, WJ .
EUROPEAN HEART JOURNAL, 1990, 11 :33-40
[8]   A MATHEMATICAL MODEL OF DILUTION CURVES FOR FLOW STUDY [J].
GOTT, FS ;
PRITCHARD, WH ;
MACINTYRE, WJ ;
MOIR, TW .
CIRCULATION RESEARCH, 1961, 9 (03) :607-&
[9]   ERYTHROCYTE TRANSIT AND NEUTROPHIL CONCENTRATION IN THE DOG LUNG [J].
HOGG, JC ;
MCLEAN, T ;
MARTIN, BA ;
WIGGS, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (03) :1217-1225
[10]  
KELBAEK H, 1987, J NUCL MED, V28, P1330