Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus

被引:252
作者
Hayden, R. T. [1 ]
Gu, Z. [1 ]
Ingersoll, J. [3 ,4 ]
Abdul-Ali, D. [3 ,4 ]
Shi, L. [2 ]
Pounds, S. [2 ]
Caliendo, A. M. [3 ,4 ]
机构
[1] St Jude Childrens Res Hosp, Dept Pathol, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Biostat, Memphis, TN 38105 USA
[3] Emory Univ, Sch Med, Dept Pathol & Lab Med, Atlanta, GA 30322 USA
[4] Emory Univ, Emory Ctr AIDS Res, Atlanta, GA 30322 USA
关键词
CELL TRANSPLANT RECIPIENTS; POLYMERASE-CHAIN-REACTION; EPSTEIN-BARR-VIRUS; VIRAL LOAD ASSAYS; DNA COPY NUMBER; ABSOLUTE QUANTITATION; QUANTIFICATION; STANDARDS;
D O I
10.1128/JCM.02620-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Quantitative real-time PCR (QRT-PCR) has been widely implemented for clinical viral load testing, but a lack of standardization and relatively poor precision have hindered its usefulness. Digital PCR offers highly precise, direct quantification without requiring a calibration curve. Performance characteristics of real-time PCR were compared to those of droplet digital PCR (ddPCR) for cytomegalovirus (CMV) load testing. Tenfold serial dilutions of the World Health Organization (WHO) and the National Institute of Standards and Technology (NIST) CMV quantitative standards were tested, together with the AcroMetrix CMV tc panel (Life Technologies, Carlsbad, CA) and 50 human plasma specimens. Each method was evaluated using all three standards for quantitative linearity, lower limit of detection (LOD), and accuracy. Quantitative correlation, mean viral load, and variability were compared. Real-time PCR showed somewhat higher sensitivity than ddPCR (LODs, 3 log(10) versus 4 log(10) copies/ml and IU/ml for NIST and WHO standards, respectively). Both methods showed a high degree of linearity and quantitative correlation for standards (R-2 >= 0.98 in each of 6 regression models) and clinical samples (R-2 = 0.93) across their detectable ranges. For higher concentrations, ddPCR showed less variability than QRT-PCR for the WHO standards and AcroMetrix standards (P < 0.05). QRT-PCR showed less variability and greater sensitivity than did ddPCR in clinical samples. Both digital and real-time PCR provide accurate CMV load data over a wide linear dynamic range. Digital PCR may provide an opportunity to reduce the quantitative variability currently seen using real-time PCR, but methods need to be further optimized to match the sensitivity of real-time PCR.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 31 条
  • [1] [Anonymous], 2010, Collaborative study to evaluate the proposed 1st [first] WHO international standard for human cytomegalovirus (HCMV) for nucleic acid amplification (NAT)- based assays
  • [2] Serious infections after unrelated donor transplantation in 136 children: Impact of stem cell source
    Barker, JN
    Hough, RE
    van Burik, JAH
    DeFor, TE
    MacMillan, ML
    O'Brien, MR
    Wagner, JE
    [J]. BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2005, 11 (05) : 362 - 370
  • [3] Properties of sufficiency and statistical tests
    Bartlett, MS
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1937, 160 (A901) : 0268 - 0282
  • [4] Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number
    Bhat, Somanath
    Herrmann, Jan
    Armishaw, Paul
    Corbisier, Philippe
    Emslie, Kerry R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) : 457 - 467
  • [5] How I treat cytomegalovirus in hematopoietic cell transplant recipients
    Boeckh, Michael
    Ljungman, Per
    [J]. BLOOD, 2009, 113 (23) : 5711 - 5719
  • [6] A Commutable Cytomegalovirus Calibrator Is Required to Improve the Agreement of Viral Load Values between Laboratories
    Caliendo, Angela M.
    Shahbazian, Mona D.
    Schaper, Carl
    Ingersoll, Jessica
    Abdul-Ali, Deborah
    Boonyaratanakornkit, Jerry
    Pang, Xiao-Li
    Fox, Julie
    Preiksaitis, Jutta
    Schoenbrunner, E. Ralf
    [J]. CLINICAL CHEMISTRY, 2009, 55 (09) : 1701 - 1710
  • [7] Digital quantification of mutant DNA in cancer patients
    Diehl, Frank
    Diaz, Luis A., Jr.
    [J]. CURRENT OPINION IN ONCOLOGY, 2007, 19 (01) : 36 - 42
  • [8] Hayden RT, 2008, J CLIN MICROBIOL, V46, P157, DOI 10.1128/JCM.01252-07
  • [9] Factors Contributing to Variability of Quantitative Viral PCR Results in Proficiency Testing Samples: a Multivariate Analysis
    Hayden, R. T.
    Yan, X.
    Wick, M. T.
    Rodriguez, A. B.
    Xiong, X.
    Ginocchio, C. C.
    Mitchell, M. J.
    Caliendo, A. M.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (02) : 337 - 345
  • [10] High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy Number
    Hindson, Benjamin J.
    Ness, Kevin D.
    Masquelier, Donald A.
    Belgrader, Phillip
    Heredia, Nicholas J.
    Makarewicz, Anthony J.
    Bright, Isaac J.
    Lucero, Michael Y.
    Hiddessen, Amy L.
    Legler, Tina C.
    Kitano, Tyler K.
    Hodel, Michael R.
    Petersen, Jonathan F.
    Wyatt, Paul W.
    Steenblock, Erin R.
    Shah, Pallavi H.
    Bousse, Luc J.
    Troup, Camille B.
    Mellen, Jeffrey C.
    Wittmann, Dean K.
    Erndt, Nicholas G.
    Cauley, Thomas H.
    Koehler, Ryan T.
    So, Austin P.
    Dube, Simant
    Rose, Klint A.
    Montesclaros, Luz
    Wang, Shenglong
    Stumbo, David P.
    Hodges, Shawn P.
    Romine, Steven
    Milanovich, Fred P.
    White, Helen E.
    Regan, John F.
    Karlin-Neumann, George A.
    Hindson, Christopher M.
    Saxonov, Serge
    Colston, Bill W.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (22) : 8604 - 8610