Model-based and wavelet approaches to induction motor on-line fault detection

被引:46
作者
Combastel, C [1 ]
Lesecq, S [1 ]
Petropol, S [1 ]
Gentil, S [1 ]
机构
[1] Inst Natl Polytech Grenoble, ENSIEG, UJF, CNRS UMR 5528,Lab Automat Grenoble, F-38402 St Martin Dheres, France
关键词
diagnosis; fault detection; monitoring; wavelet transform; induction machines;
D O I
10.1016/S0967-0661(01)00158-7
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper compares model-based and signal-based approaches to induction motor fault detection. A Park model was used to describe the electrical variables. System faults such as stator winding failures or broken rotor bars are investigated. Parameter variations due to heating are considered. The identification of a single parameter, modelling the temperature effect, has allowed good detection within a classical analytical redundancy scheme. The wavelet transform is applied to the residuals rather than to the raw stator currents, in order to filter variations due to variable speed. An experimental benchmark (Leroy-Sommer, 1.1 kW) has allowed a practical comparison of the methods. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:493 / 509
页数:17
相关论文
共 24 条
[1]   Wavelet thresholding via a Bayesian approach [J].
Abramovich, F ;
Sapatinas, T ;
Silverman, BW .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1998, 60 :725-749
[2]  
[Anonymous], THESIS U C BERNARD L
[3]  
ARNANZ R, 2000, P IFAC SAF 2000 BUD, P1145
[4]  
BOUATTOUR J, 2000, P IFAC SAF 2000 BUD, P992
[5]  
CHAMPENOIS G, 2000, IFAC S SICICA 2000 A
[6]  
COMBASTEL C, 2000, P IFAC SAF 2000 BUD, P1133
[7]  
COMBASTEL C, 1999, P EUR CONTR C 1999 K
[8]   IDEAL SPATIAL ADAPTATION BY WAVELET SHRINKAGE [J].
DONOHO, DL ;
JOHNSTONE, IM .
BIOMETRIKA, 1994, 81 (03) :425-455
[9]  
FRANK PM, 2000, P IFAC SAF BUD HUNG, P16
[10]   Fault detection based on adaptive parity equations and single-parameter tracking [J].
Hofling, T ;
Isermann, R .