Internal currents in response to a load change during fuel cell start-up

被引:18
作者
Didierjean, Sophie [1 ]
Lamibrac, Adrien [1 ]
Geneston, Thierry [2 ]
Rakotondrainibe, Andre [2 ]
Maranzana, Gael [1 ]
Rozier, Erik [2 ]
Beille, Florent [2 ]
Lottin, Olivier [1 ]
机构
[1] LEMTA CNRS Nancy Univ, F-54504 Vandoeuvre Les Nancy, France
[2] Hel Hydrogen Power, F-13545 Aix En Provence 04, France
关键词
Proton exchange membrane fuel cell; Segmented; Dynamic behaviour; Start-up; DYNAMIC-BEHAVIOR;
D O I
10.1016/j.ijhydene.2012.01.064
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The transient response of proton exchange membrane fuel cells during start-up is an important issue for backup power systems. These require a very short start-up time which limits the use of batteries during a blackout. In this study the fuel cell was initially inerted with nitrogen at the cathode and thus the start-up procedures occurred in two stages: gas supply in open-circuit and load connection. The influence of the current time-profile, the cell voltage at the connection and the gas flow rates on the voltage variation were investigated using a segmented fuel cell permitting the measurements of the internal local currents. We found that the voltage during the filling of the cathode is not sufficient to determine which fraction of the cathode was filled with oxygen. In the case of a step change in current, the start-up time decreases as the voltage at the moment the cell is connected increases. In response to a ramp, the asymptotic power value is reached quickly. Copyright (C) 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:6798 / 6807
页数:10
相关论文
共 17 条
[1]   PEM fuel cells modeling and analysis through current and voltage transient behaviors [J].
Adzakpa, K. P. ;
Agbossou, K. ;
Dube, Y. ;
Dostie, M. ;
Fournier, M. ;
Poulin, A. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) :581-591
[2]   Measurement of the current distribution along a single flow channel of a solid polymer fuel cell [J].
Brett, DJL ;
Atkins, S ;
Brandon, NP ;
Vesovic, V ;
Vasileiadis, N ;
Kucernak, AR .
ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (11) :628-632
[3]  
Freunberger SA, 2006, J ELECTROCHEM SOC, V153, P2158
[4]   A simple dynamic model for polymer electrolyte membrane fuel cell (PEMFC) power modules: Parameter estimation and model prediction [J].
Kim, Hyun-il ;
Cho, Chan Young ;
Nam, Jin Hyun ;
Shin, Donghoon ;
Chung, Tae-Yong .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (08) :3656-3663
[5]   The effect of reservoirs and fuel dilution on the dynamic behavior of a PEMFC [J].
Kim, S ;
Shimpalee, S ;
Van Zee, JW .
JOURNAL OF POWER SOURCES, 2004, 137 (01) :43-52
[6]   Experimental characterization of internal currents during the start-up of a proton exchange membrane fuel cell [J].
Lamibrac, A. ;
Maranzana, G. ;
Lottin, O. ;
Dillet, J. ;
Mainka, J. ;
Didierjean, S. ;
Thomas, A. ;
Moyne, C. .
JOURNAL OF POWER SOURCES, 2011, 196 (22) :9451-9458
[7]   Segmented polymer electrolyte membrane fuel cells-A review [J].
Perez, Luis C. ;
Brandao, Lucia ;
Sousa, Jose M. ;
Mendes, Adelio .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :169-185
[8]   The effect of air stoichiometry change on the dynamic behavior of a proton exchange membrane fuel cell [J].
Qu, Shuguo ;
Li, Xiaojin ;
Hou, Ming ;
Shao, Zhigang ;
Yi, Baolian .
JOURNAL OF POWER SOURCES, 2008, 185 (01) :302-310
[9]   Measuring the Current Distribution with Submillimeter Resolution in PEFCs III. Influence of the Flow Field Geometry [J].
Reum, Mathias ;
Wokaun, Alexander ;
Buechi, Felix N. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (10) :B1225-B1231
[10]   Measuring the Current Distribution with Sub-Millimeter Resolution in PEFCs [J].
Reum, Mathias ;
Freunberger, Stefan A. ;
Wokaun, Alexander ;
Buechi, Felix N. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (03) :B301-B310