Percutaneous gastrostomy and gastrojejunostomy with gastropexy: Experience in 701 procedures

被引:78
作者
Dewald, CL [1 ]
Hiette, PO [1 ]
Sewall, LE [1 ]
Fredenberg, PG [1 ]
Palestrant, AM [1 ]
机构
[1] St Josephs Hosp & Med Ctr, Barrow Neurol Inst, Dept Radiol, Phoenix, AZ USA
关键词
gastrojejunostomy; gastrostomy; interventional procedures; complications; stomach; interventional procedure;
D O I
10.1148/radiology.211.3.r99ma04651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the safety and efficacy of fluoroscopically directed percutaneous gastrostomy and gastrojejunostomy catheter placement with gastropexy. MATERIALS AND METHODS: The authors retrospectively reviewed the charts from 643 patients referred for fluoroscopically directed percutaneous gastrostomy or gastrojejunostomy during a 91/2-year period. In 615 patients, placement was attempted with use of three T-fastener gastropexy devices followed by percutaneous gastric puncture. Placement of a 14-F gastrostomy or gastrojejunostomy catheter was then accomplished with the Seldinger technique. RESULTS: A catheter could not be placed in 28 patients (4.4%) owing to overlying viscera or prior gastric surgery. In the remaining patients, 701 procedures, including revisions, were performed, including 643 gastrojejunostomies (92%) and 58 gastrostomies (8.3%). The success rate for catheter placement was 100%. Revision was necessary in 83 instances in 64 patients (13.5%). Forty-six (55%) of these were attributed to tube dislodgment, but only two repeat gastric punctures were necessary secondary to tract disruption. There were three major complications (0.5%) and 29 minor complications (5.3%). No complications were attributed directly to gastropexy. Thirty-day follow-up data were available for 393 patients (64%), and 14-day follow-up data were available for 550 (89%). The 30-day mortality rate was 5.8% (23 of 393 patients); none of the deaths were related to the procedure. CONCLUSION: Fluoroscopically directed percutaneous placement of gastrostomy and gastrojejunostomy catheters with routine gastropexy is a safe procedure. Catheter revision was necessary in 13% of patients and was usually secondary to tube dislodgment, with tract disruption an unusual complication.
引用
收藏
页码:651 / 656
页数:6
相关论文
共 20 条
  • [1] PERCUTANEOUS GASTROSTOMY AND GASTROJEJUNOSTOMY - ADDITIONAL EXPERIENCE IN 519 PROCEDURES
    BELL, SD
    CARMODY, EA
    YEUNG, EY
    THURSTON, WA
    SIMONS, ME
    HO, CS
    [J]. RADIOLOGY, 1995, 194 (03) : 817 - 820
  • [2] CONTROLLED PERCUTANEOUS GASTROSTOMY - NYLON T-FASTENER FOR FIXATION OF THE ANTERIOR GASTRIC WALL
    BROWN, AS
    MUELLER, PR
    FERRUCCI, JT
    [J]. RADIOLOGY, 1986, 158 (02) : 543 - 545
  • [3] CHUNG RS, 1990, AM SURGEON, V56, P134
  • [4] PERCUTANEOUS ENTEROSTOMY WITH THE COPE SUTURE ANCHOR
    COLEMAN, CC
    COONS, HG
    COPE, C
    DERAUF, BJ
    KRENZEL, C
    EPSTEIN, DH
    SCHLAM, BW
    CASTANEDA, F
    HOUGH, JP
    MORADIAN, GP
    [J]. RADIOLOGY, 1990, 174 (03) : 889 - 891
  • [5] COPE C, 1986, AM J ROENTGENOL, V146, P160, DOI 10.2214/ajr.146.1.160
  • [6] SIMPLIFIED PERCUTANEOUS GASTROSTOMY
    DEUTSCH, LS
    KANNEGIETER, L
    VANSON, DT
    MILLER, DP
    BRANDON, JC
    [J]. RADIOLOGY, 1992, 184 (01) : 181 - 183
  • [7] PERCUTANEOUS FEEDING GASTROSTOMY WITH THE SELDINGER TECHNIQUE - REVIEW OF 252 PATIENTS
    HALKIER, BK
    HO, CS
    YEE, ACN
    [J]. RADIOLOGY, 1989, 171 (02) : 359 - 362
  • [8] FLUOROSCOPICALLY GUIDED PERCUTANEOUS GASTROSTOMY AND GASTROENTEROSTOMY - ANALYSIS OF 158 CONSECUTIVE CASES
    HICKS, ME
    SURRATT, RS
    PICUS, D
    MARX, MV
    LANG, EV
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) : 725 - 728
  • [9] HICKS ME, 1993, PEDIAT DIS 4 SERIES, P358
  • [10] PERCUTANEOUS GASTROSTOMY FOR JEJUNAL FEEDING
    HO, CS
    [J]. RADIOLOGY, 1983, 149 (02) : 595 - 596