Molecular pincers: Antibody-based homogeneous protein sensors

被引:55
作者
Heyduk, Ewa [1 ]
Dummit, Benjamin [2 ]
Chang, Yie-Hwa [2 ]
Heyduk, Tomasz [1 ]
机构
[1] St Louis Univ, Edward A Doisy Dept Biochem & Mol Biol, Sch Med, St Louis, MO 63104 USA
[2] LLC, St Louis, MO 63110 USA
关键词
D O I
10.1021/ac8004154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe here a new homogeneous antibody-based protein sensor design (molecular pincers) that allows rapid and sensitive detection of a specific protein in solution. In the presence of the target protein these sensors produce fluorescence signal derived from target-dependent annealing of short complementary fluorochrome-labeled oligonucleotides attached to a pair of target-specific antibodies via nanometer-scale flexible linkers. The sensors allow near-instantaneous detection of the target with sensitivity and specificity approaching that of enzyme-linked immunosorbent assay (ELISA) but requiring no sample manipulation other then the addition of the sample to the sensor mix. We used cardiac troponin I and C-reactive protein as the targets to validate these desirable properties of the sensors. Due to the availability of antibodies to thousands of interesting targets and the straightforward design blueprint of the sensors we expect their wide-ranging applications in research and medical diagnosis, especially when simplicity, high throughput, and short detection time are essential.
引用
收藏
页码:5152 / 5159
页数:8
相关论文
共 30 条
[1]   CARDIAC TROPONIN-I - A MARKER WITH HIGH SPECIFICITY FOR CARDIAC INJURY [J].
ADAMS, JE ;
BODOR, GS ;
DAVILAROMAN, VG ;
DELMEZ, JA ;
APPLE, FS ;
LADENSON, JH ;
JAFFE, AS .
CIRCULATION, 1993, 88 (01) :101-106
[2]   ACUTE MYOCARDIAL-INFARCTION AND CORONARY REPERFUSION - SERUM CARDIAC MARKERS FOR THE 1990S [J].
APPLE, FS .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1992, 97 (02) :217-226
[3]   Troponin: the biomarker of choice for the detection of cardiac injury [J].
Babuin, L ;
Jaffe, AS .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2005, 173 (10) :1191-1202
[4]   Release kinetics of serum cardiac troponin I in ischemic myocardial injury [J].
Bertinchant, JP ;
Larue, C ;
Pernel, I ;
Ledermann, B ;
FabbroPeray, P ;
Beck, L ;
Calzolari, C ;
Trinquier, S ;
Nigond, J ;
Pau, B .
CLINICAL BIOCHEMISTRY, 1996, 29 (06) :587-594
[5]   CARDIAC-SPECIFIC TROPONIN-I RADIOIMMUNOASSAY IN THE DIAGNOSIS OF ACUTE MYOCARDIAL-INFARCTION [J].
CUMMINS, B ;
AUCKLAND, ML ;
CUMMINS, P .
AMERICAN HEART JOURNAL, 1987, 113 (06) :1333-1344
[6]   C-reactive protein: a nontraditional serum marker of cardiovascular risk [J].
de Ferranti, Sarah D. ;
Rifai, Nader .
CARDIOVASCULAR PATHOLOGY, 2007, 16 (01) :14-21
[7]  
DIAMANDIS EP, 1988, CLIN BIOCHEM, V21, P139, DOI 10.1016/0009-9120(88)90001-X
[8]   ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) QUANTITATIVE ASSAY OF IMMUNOGLOBULIN-G [J].
ENGVALL, E ;
PERLMANN, P .
IMMUNOCHEMISTRY, 1971, 8 (09) :871-&
[9]   USE OF CARDIAC TROPONIN-I AS A MARKER OF PERIOPERATIVE MYOCARDIAL-ISCHEMIA [J].
ETIEVENT, JP ;
CHOCRON, S ;
TOUBIN, G ;
TABERLET, C ;
ALWAN, K ;
CLEMENT, F ;
CORDIER, A ;
SCHIPMAN, N ;
KANTELIP, JP .
ANNALS OF THORACIC SURGERY, 1995, 59 (05) :1192-1194
[10]   Protein detection using proximity-dependent DNA ligation assays [J].
Fredriksson, S ;
Gullberg, M ;
Jarvius, J ;
Olsson, C ;
Pietras, K ;
Gústafsdóttir, SM ;
Östman, A ;
Landegren, U .
NATURE BIOTECHNOLOGY, 2002, 20 (05) :473-477