An immunosensor for ferritin based on agarose hydrogel

被引:30
作者
Zhang, XH [1 ]
Wang, SF [1 ]
Hu, M [1 ]
Xiao, Y [1 ]
机构
[1] Hubei Univ, Fac Chem & Mat Sci, Wuhan 430062, Peoples R China
关键词
immunosensor; ferritin and ferritin antibody; agarose hydrogel; electrochemistry;
D O I
10.1016/j.bios.2005.10.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel electrochemical immunosensor for determination of ferritin in serum has been proposed. The immunosensor was prepared by immobilizing ferritin antibody (FeAb) on a glassy carbon electrode (GCE) based on agarose hydrogel. The modification procedure of the immunosensor was characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The effects of amount of FeAb, incubation time and temperature on the immunosensor were explored to provide optimum analytical performance. The determination of ferritin was based on the change in DPV response before and after the antibody (Ab)-antigen (Ag) reaction. Tests result indicated that FeAb in the device microenvironment had biological activity. The detection limit for ferritin was 1.5 x 10(-5) gl(-1) and the linear range was 5-50 x 10(-5) gl(-1) with a correlation coefficient of 0.996. The storage stability was acceptable in pH 7.0 phosphate buffer saline (PBS) solution at 4 degrees C for 10 days. The proposed immunosensor provides a new promising method for the clinical immunoassay of ferritin. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2180 / 2183
页数:4
相关论文
共 20 条
[1]   IMMUNORADIOMETRIC ASSAY FOR FERRITIN IN SERUM OF NORMAL SUBJECTS AND PATIENTS WITH IRON-DEFICIENCY AND IRON OVERLOAD [J].
ADDISON, GM ;
BEAMISH, MR ;
JACOBS, A ;
HALES, CN ;
HODGKINS, M ;
LLEWELLIN, P .
JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (04) :326-+
[2]   IRON TRANSPORT AND STORAGE PROTEINS [J].
AISEN, P ;
LISTOWSKY, I .
ANNUAL REVIEW OF BIOCHEMISTRY, 1980, 49 :357-393
[3]   MECHANISM ANALYSIS OF ELECTROCHEMICAL REACTIONS INVOLVING HOMOGENEOUS CHEMICAL STEPS - THE ELECTRODIMERIZATION OF 4-METHOXYBIPHENYL [J].
AMATORE, C ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 144 (1-2) :59-67
[4]   IRON TRANSPORT AND STORAGE [J].
CRICHTON, RR ;
CHARLOTEAUXWAUTERS, M .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1987, 164 (03) :485-506
[5]   Immunosensor for Mycobacterium tuberculosis on screen-printed carbon electrodes [J].
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2035-2043
[6]   Immunological assay for carbohydrate antigen 19-9 using an electrochemical immunosensor and antigen immobilization in titania sol-gel matrix [J].
Du, D ;
Yan, F ;
Liu, SL ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 283 (1-2) :67-75
[7]   Immunochemical detection of polycyclic aromatic hydrocarbons (PAHs) [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
ANALYTICAL LETTERS, 2002, 35 (08) :1269-1300
[8]   SOLID-PHASE RADIOIMMUNOASSAY FOR SERUM FERRITIN [J].
HALLIDAY, JW ;
GERA, KL ;
POWELL, LW .
CLINICA CHIMICA ACTA, 1975, 58 (03) :207-214
[9]  
HANS GE, 1976, ANGEW CHEM INT EDIT, V15, P525
[10]   Ferritins: Molecular properties, iron storage function and cellular regulation [J].
Harrison, PM ;
Arosio, P .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1996, 1275 (03) :161-203