Dynamic application of microprojection arrays to skin induces circulating protein extravasation for enhanced biomarker capture and detection

被引:36
作者
Coffey, Jacob W. [1 ,2 ]
Meliga, Stefano C. [1 ,2 ]
Corrie, Simon R. [1 ,2 ,3 ]
Kendall, Mark A. F. [1 ,2 ,3 ,4 ]
机构
[1] Univ Queensland, Delivery Drugs & Genes Grp, Australian Inst Bioengn & Nanotechnol, Brisbane, Qld 4072, Australia
[2] Univ Queensland, ARC Ctr Excellence Convergent BionanoSci & Techno, Brisbane, Qld 4072, Australia
[3] Univ Queensland, Australian Infect Dis Res Ctr, Brisbane, Qld 4072, Australia
[4] Univ Queensland, Fac Med & Biomed Sci, Brisbane, Qld 4072, Australia
基金
英国医学研究理事会; 澳大利亚研究理事会;
关键词
Biomarkers; Extravasation; Microneedles; Diagnosis; Sampling; Skin; INTERSTITIAL FLUID; PLASMA PROTEOME; IN-VITRO; MICRONEEDLE; BLOOD; MACROMOLECULES; PERMEABILITY; TRANSPORT; DENSITY; ALBUMIN;
D O I
10.1016/j.biomaterials.2016.01.015
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Surface modified microprojection arrays are a needle-free alternative to capture circulating biomarkers from the skin in vivo for diagnosis. The concentration and turnover of biomarkers in the interstitial fluid, however, may limit the amount of biomarker that can be accessed by microprojection arrays and ultimately their capture efficiency. Here we report that microprojection array insertion induces protein extravasation from blood vessels and increases the concentration of biomarkers in skin, which can synergistically improve biomarker capture. Regions of blood vessels in skin were identified in the upper dermis and subcutaneous tissue by multi-photon microscopy. Insertion of microprojection array designs with varying projection length (40-190 mu m), density (5000-20,408 proj.cm(-2)) and array size (4-36 mm(2)) did not affect the degree of extravasation. Furthermore, the location of extravasated protein did not correlate with projection penetration to these highly vascularised regions, suggesting extravasation was not caused by direct puncture of blood vessels. Biomarker extravasation was also induced by dynamic application of flat control surfaces, and varied with the impact velocity, further supporting this conclusion. The extravasated protein distribution correlated well with regions of high mechanical stress generated during insertion, quantified by finite element models. Using this approach to induce extravasation prior to microprojection array-based biomarker capture, anti-influenza IgG was captured within a 2 min application time, demonstrating that extravasation can lead to rapid biomarker sampling and significantly improved microprojection array capture efficiency. These results have broad implications for the development of transdermal devices that deliver to and sample from the skin. Crown Copyright (C) 2016 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:130 / 143
页数:14
相关论文
共 47 条
[1]
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum [J].
Anderson, N. Leigh .
CLINICAL CHEMISTRY, 2010, 56 (02) :177-185
[2]
The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[3]
In vivo assessment of safety of microneedle arrays in human skin [J].
Bal, Suzanne M. ;
Caussin, Julia ;
Pavel, Stan ;
Bouwstra, Joke A. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 35 (03) :193-202
[4]
Surface Modifications of Microprojection Arrays for Improved Biomarker Capture in the Skin of Live Mice [J].
Bhargav, Aarshi ;
Muller, David A. ;
Kendall, Mark A. F. ;
Corrie, Simon R. .
ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (05) :2483-2489
[5]
PLASMA-PROTEIN DYNAMICS - ALBUMIN AND IGG CAPILLARY-PERMEABILITY, EXTRAVASCULAR MOVEMENT AND REGIONAL BLOOD-FLOW IN UNANESTHETIZED RABBITS [J].
BILL, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1977, 101 (01) :28-42
[6]
Bilo RC, 2013, BLUNT FORCE TRAUMA B, P63
[7]
The cutaneous microcirculation: Ultrastructure and microanatomical organization [J].
Braverman, IM .
MICROCIRCULATION, 1997, 4 (03) :329-340
[8]
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring [J].
Cengiz, Eda ;
Tamborlane, William V. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S11-S16
[9]
Dry-coated microprojection array patches for targeted delivery of immunotherapeutics to the skin [J].
Chen, Xianfeng ;
Prow, Tarl W. ;
Crichton, Michael L. ;
Jenkins, Derek W. K. ;
Roberts, Michael S. ;
Frazer, Ian H. ;
Fernando, Germain J. P. ;
Kendall, Mark A. F. .
JOURNAL OF CONTROLLED RELEASE, 2009, 139 (03) :212-220
[10]
Early circulating biomarker detection using a wearable microprojection array skin patch [J].
Coffey, Jacob W. ;
Corrie, Simon R. ;
Kendall, Mark A. F. .
BIOMATERIALS, 2013, 34 (37) :9572-9583