A new method of fixation in osteoporotic bone - A preliminary report

被引:14
作者
Drew, T [1 ]
Allcock, P
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Orthopaed & Trauma Surg, Dundee DD1 9SY, Scotland
[2] Tayside Univ Hosp, Ninewells Hosp & Med Sch, Dept Orthopaed & Trauma Surg, Dundee DD1 9SY, Scotland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2002年 / 33卷 / 08期
关键词
fixatiom; screw; osteoporotic; plug;
D O I
10.1016/S0020-1383(02)00047-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Over-tightening of cortical bone screws in osteoporotic bone results ill weak fixation. Once a screw is over-tightened and the bone thread form is stripped, there are limited means at the Surgeon's disposal to rescue the situation, none of them entirely satisfactory. We describe a simple device that is specifically designed to resolve this problem. It consists of a nylon cavity plug and applicator. The plug is inserted into the stripped hole and the screw re-applied and tightened in the normal manner. The Plug expands and forms a load-bearing region on the inner face of the bone. Tests on osteoporotic cadavaric bone have shown that the plug effectively re-establishes screw fixation. When compared to an over-tightened screw, the plug is at least twice as resistant to loads acting to Pull the screw out of the Surrounding bone. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:685 / 689
页数:5
相关论文
共 9 条
[1]   Use of a Dall-Miles plate and cables for the fixation of a periprosthetic tibial fracture [J].
Banim, RH ;
Fletcher, M ;
Warren, P .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :131-133
[2]   USE OF BONE CEMENT AS AN ADJUNCT TO INTERNAL-FIXATION OF SUPRACONDYLAR FRACTURES OF OSTEOPOROTIC FEMURS [J].
BENUM, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (01) :52-56
[3]   USE OF POLYMETHYLMETHACRYLATE TO ENHANCE SCREW FIXATION IN BONE [J].
CAMERON, HU ;
JACOB, R ;
MACNAB, I ;
PILLIAR, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (05) :655-656
[4]  
HARRINGTON KD, 1975, J BONE JOINT SURG AM, V57, P744
[5]   AN ALTERNATIVE TO SCREWS FOR PLATING OSTEOPOROTIC BONE [J].
KING, TSJ ;
CEBON, D .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (01) :79-82
[6]  
PARTRIDGE A, 1977, LANCET, V8015, P808
[7]   METHYLMETHACRYLATE AS AN ADJUNCT IN INTERNAL-FIXATION OF INTERTROCHANTERIC FRACTURES OF FEMUR [J].
SCHATZKER, J ;
HAERI, GB ;
CHAPMAN, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1978, 18 (10) :732-735
[8]  
STRUPP D, 1990, UWSF Z UMWELTCHEM OK, V2, P151
[9]   Dall-Miles plating for periprosthetic B1 fractures of the femur [J].
Tadross, TSF ;
Nanu, AM ;
Buchanan, MJ ;
Checketts, RG .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :47-51