We describe analytical procedures for trace element determinations developed at the CNRS Service d'Analyse des Roches et des Mineraux (SARM) and report results obtained for five geochemical reference materials: basalt BR, diorite DR-N, serpentinite UB-N, anorthosite AN-G and granite GH. Results for rare earth elements, U and Th are also reported for other reference materials including dunite DTS-1, peridotite PCC-1 and basalt BIR-1. All rocks were decomposed using alkali fusion. Analyses were done by flow injection ICP-MS and by on-line low pressure liquid chromatography (LC)-ICP-MS for samples containing very low REE, U and Th concentrations. This latter method yielded limits of determination much lower than data by direct introduction and eliminated possible isobaric interference on these elements. Although results agree with most of the working values, when available, results for some elements differed slightly from the recommended concentrations. In these cases, we propose new values for Co, Y and Zn in basalt BR, Zr in diorite DR-N, Sr and U in granite GH, and Go and Y in anorthosite AN-G. Furthermore, although the Sb concentration measured in AN-G was very close to our limit of determination, our value (0.3 +/- 0.1 mug g(-1)) is much lower than the reported working value of 1.4 +/- 0.2 mug g(-1). These new values would need to be confirmed by a new inter-laboratory programme to further characterise these reference materials. Results obtained for REE, Th and U concentrations using the on-line low pressure LC-ICP-MS yielded good limits of determination (ng g(-1) to sub-ng g(-1) for rocks and ng l(-1) to sub-ng l(-1) for natural waters) and accurate results. The efficiency of the matrix separation allowed accurate measurements of Eu without the need to correct the BaO isobaric interference for samples having Ba/Eu ratios as high as 27700. For REE concentrations in PCC-1 and DTS-1, differences with values reported in. the literature are interpreted, as resulting from possible heterogeneity of the reference materials. Thorium and U values are proposed for these two samples, as well, as for AN-G and UB-N.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 16 条
[1]  
Debrah E, 1999, ATOM SPECTROSC, V20, P1
[2]  
DENOYER ER, 1993, ATOM SPECTROSC, V14, P55
[3]   COMPILATION REPORT (1966-1987) ON TRACE-ELEMENTS IN 5 CRPG GEOCHEMICAL REFERENCE SAMPLES - BASALT BR, GRANITES, GA AND GH, MICAS, BIOTITE MICA-FE AND PHLOGOPITE MICA-MG [J].
GOVINDARAJU, K ;
ROELANDTS, I .
GEOSTANDARDS NEWSLETTER, 1988, 12 (01) :119-201
[4]   2ND REPORT (1993) ON THE 1ST 3 GIT-IWG ROCK REFERENCE SAMPLES - ANORTHOSITE FROM GREENLAND, AN-G BASALTE-DESSEY-LA-COTE, BE-N GRANITE-DE-BEAUVOIR, MA-N [J].
GOVINDARAJU, K ;
ROELANDTS, I .
GEOSTANDARDS NEWSLETTER, 1993, 17 (02) :227-294
[6]  
Govindaraju K., 1995, GEOSTANDARDS NEWSLET, V19
[7]  
Govindaraju K., 1994, GEOSTANDARDS NEWSLET, VXVIII
[8]   DETERMINATION OF TC-99, TH-230 AND U-234 IN SOILS BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING FLOW-INJECTION PRECONCENTRATION [J].
HOLLENBACH, M ;
GROHS, J ;
MAMICH, S ;
KROFT, M ;
DENOYER, ER .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :927-933
[9]   Determination of the REE in geological reference materials DTS-1 (dunite) and PCC-1 (Peridotite) by ultrasonic and microconcentric desolvating nebulisation ICP-MS [J].
Jain, JC ;
Field, MP ;
Neal, CR ;
Ely, JC ;
Sherrell, RM .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2000, 24 (01) :65-72
[10]   TRACE-ELEMENT ANALYSIS OF BASALT BIR-1 BY ID-SSMS, HPLC AND LIMS [J].
JOCHUM, KP ;
REHKAMPER, M ;
SEUFERT, HM .
GEOSTANDARDS NEWSLETTER, 1994, 18 (01) :43-51