Single grain laser luminescence (SGLL) measurements using a novel automated reader

被引:100
作者
Duller, GAT [1 ]
Botter-Jensen, L
Murray, AS
Truscott, AJ
机构
[1] Univ Wales, Inst Geog & Earth Sci, Aberystwyth SY23 3DB, Dyfed, Wales
[2] Riso Natl Lab, DK-4000 Roskilde, Denmark
[3] Riso Natl Lab, Nord Lab Thermoluminescence Dating, DK-4000 Roskilde, Denmark
基金
英国自然环境研究理事会;
关键词
luminescence; quartz; dose reconstruction; optically stimulated luminescence;
D O I
10.1016/S0168-583X(99)00488-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optically stimulated luminescence (OSL) is used widely for reconstructing past radiation exposure, either in connection with accidental release of radionuclides into the environment, or for dating the time since geological materials were deposited. Measurements of the optically stimulated luminescence properties of crystals are conventionally undertaken on groups of many hundred to many thousand sand-sized (90-300 mu m) grains. However, it has long been known that different grains may have different luminescence properties (e.g., sensitivity to dose) and that more information could be gained if single grains could be measured separately, and thus avoid the effect of averaging. Here we describe an automated system that makes the routine measurement of OSL of a large number of single grains feasible for the first time. The concepts underlying the design are described, and initial measurements demonstrate that a reproducibility of 3% can be achieved in repeated OSL measurements of a single grain of Al2O3:C. Measurements on a geological quartz sample demonstrate that the system can also analyse natural samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:506 / 514
页数:9
相关论文
共 23 条
[1]  
Aitken M.J., 1998, INTRO OPTICAL DATING
[2]   The development of retrospective luminescence dosimetry for dose reconstruction in areas downwind of Chernobyl [J].
Bailiff, IK .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :411-419
[3]  
BAILIFF IK, 1996, 8 INT LED C CANB
[4]  
Botter-Jensen L, 1999, RADIAT PROT DOSIM, V84, P335, DOI 10.1093/oxfordjournals.rpd.a032750
[5]  
BOTTERJENSEN L, 1991, NUCL TRACKS RAD MEAS, V18, P257
[6]  
BOTTERJENSEN L, 1992, NUCL TRACKS RAD MEAS, V20, P549
[7]  
BOTTERJENSEN L, 1988, NUCL TRACKS RAD MEAS, V14, P177
[8]   Al2O3:C as a sensitive OSL dosemeter for rapid assessment of environmental photon dose rates [J].
BotterJensen, L ;
Larsen, NA ;
Markey, BG ;
McKeever, SWS .
RADIATION MEASUREMENTS, 1997, 27 (02) :295-298
[9]   LUMINESCENCE DATING USING SINGLE ALIQUOTS - METHODS AND APPLICATIONS [J].
DULLER, GAT .
RADIATION MEASUREMENTS, 1995, 24 (03) :217-226
[10]   A luminescence imaging system based on a CCD camera [J].
Duller, GAT ;
BotterJensen, L ;
Markey, BG .
RADIATION MEASUREMENTS, 1997, 27 (02) :91-99