Design and testing of an aerosol sheath inlet for high resolution measurements with a DMA

被引:30
作者
Chen, DR
Pui, DYH
Mulholland, GW
Fernandez, M
机构
[1] Univ Minnesota, Particle Technol Lab, Dept Mech Engn, Minneapolis, MN 55455 USA
[2] NIST, Gaithersburg, MD 20899 USA
关键词
D O I
10.1016/S0021-8502(98)00767-8
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A modified aerosol/sheath inlet was designed for a differential mobility analyzer (DMA) for high resolution measurements based on field model calculations which include fluid flow, electric field, and convective/diffusive transport. To avoid the predicted flow recirculation for the current inlet design at an aerosol-to-sheath flow ratio of 0.05, the slit width is reduced and aerodynamically shaped so that the sheath velocity and aerosol velocity more nearly match. Numerical results are presented comparing the fluid flow of the old and new inlet. Problems associated with the old inlet include: flow unsteadiness at a flow ratio of 0.025, voltage shift at the peak particle concentration as a function of the flow ratio, and the historical observation that, while performing tandem differential mobility analyzer measurements (TDMA), the voltage applied on the second DMA for the peak particle concentration is higher than that for the first. Measurements demonstrate that all these problems are reduced or eliminated with the new inlet design. The TDMA measurements include flow ratios of 0.1, 0.05, 0.025 and 0.0125 at sheath flows of 166 and 333 cm(3) s(-1) (10 and 20 l min(-1)). The challenge of performing measurements at these low flow ratios will be discussed including flow calibration, flow matching, and pressure monitoring. The new inlet is applied to the measurement of the National Institute of Standards and Technology 0.1 mu m Standard Reference Material 1963, and it is shown that the DMA can accurately measure the standard deviation of this narrowly distributed aerosol (sigma/D-p = 0.02). (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:983 / 999
页数:17
相关论文
共 10 条
[1]   Mobility shift in the differential mobility analyzer due to Brownian diffusion and space-charge effects [J].
Alonso, M ;
Kousaka, Y .
JOURNAL OF AEROSOL SCIENCE, 1996, 27 (08) :1201-1225
[2]  
CAMATA RP, 1996, 15 ANN C AAAR 96 14
[3]   Neurological improvement of Wilson's disease after liver transplantation [J].
Chen, CL ;
Chen, YS ;
Lui, CC ;
Hsu, SP .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (1-2) :497-498
[4]   Numerical modeling of the performance of differential mobility analyzers for nanometer aerosol measurements [J].
Chen, DR ;
Pui, DYH .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (06) :985-1004
[5]   USE OF THE ELECTROSTATIC CLASSIFICATION METHOD TO SIZE 0.1 MU-M SRM PARTICLES - A FEASIBILITY STUDY [J].
KINNEY, PD ;
PUI, DYH ;
MULHOLLAND, GW ;
BRYNER, NP .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1991, 96 (02) :147-176
[6]  
Knutson E. O., 1975, Journal of Aerosol Science, V6, P453, DOI 10.1016/0021-8502(75)90061-0
[7]   EFFECT OF BROWNIAN DIFFUSION ON ELECTRICAL CLASSIFICATION OF ULTRAFINE AEROSOL-PARTICLES IN DIFFERENTIAL MOBILITY ANALYZER [J].
KOUSAKA, Y ;
OKUYAMA, K ;
ADACHI, M ;
MIMURA, T .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1986, 19 (05) :401-407
[8]   SUBMICRON AEROSOL STANDARD AND PRIMARY, ABSOLUTE CALIBRATION OF CONDENSATION NUCLEI COUNTER [J].
LIU, BYH ;
PUI, DYH .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1974, 47 (01) :155-171
[9]   Selection of calibration particles for scanning surface inspection systems [J].
Mulholland, GW ;
Bryner, N ;
Liggett, W ;
Scheer, BW ;
Goodall, RK .
FLATNESS, ROUGHNESS, AND DISCRETE DEFECT CHARACTERIZATION FOR COMPUTER DISKS, WAFERS, AND FLAT PANEL DISPLAYS, 1996, 2862 :104-118
[10]   APPLICATION OF THE TANDEM DIFFERENTIAL MOBILITY ANALYZER TO STUDIES OF DROPLET GROWTH OR EVAPORATION [J].
RADER, DJ ;
MCMURRY, PH .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (05) :771-787