Towards autonomous environmental monitoring systems

被引:46
作者
Sequeira, M [1 ]
Bowden, M [1 ]
Minogue, E [1 ]
Diamond, D [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Sch Chem Sci, Dublin 9, Ireland
关键词
micro-fluidic system; light source; optical stability; silicon; glass; polymers; fabrication;
D O I
10.1016/S0039-9140(01)00601-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concept of micro total analysis systems (muTAS) or Lab-on-a-chip is based on the twin strategies of integration and miniaturisation that have been so successful in the electronics industry. This paper will look at the materials issues, particularly with respect to the new polymeric materials that are becoming available, and strategies for integrating optical (colorimetric) detection. The influence of breakthroughs in apparently unrelated areas on the range of chemistries that can be applied will be illustrated. For environmental monitoring, the further integration of wireless communications with micro-dimensioned analytical instruments and sensors will become the ultimate driving force. The emergence of these compact, self-sustaining, networked instruments will have enormous impact on all field-based environmental measurements. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:355 / 363
页数:9
相关论文
共 23 条
[1]  
Daridon A, 2000, MESA MG, P303
[2]   Chemical sensing using an integrated microfluidic system based on the Berthelot reaction [J].
Daridon, A ;
Sequeira, M ;
Pennarun-Thomas, G ;
Dirac, H ;
Krog, JP ;
Gravesen, P ;
Lichtenberg, J ;
Diamond, D ;
Verpoorte, E ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :235-243
[3]   Lab-on-a-chip: A revolution in biological and medical sciences. [J].
Figeys, D ;
Pinto, D .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :330A-335A
[4]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[5]  
HARRISON DJ, 1992, IEEE SOL STAT SENS A, P110
[6]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[7]  
KROG JP, 2000, P 4 INT S MICR AN SY, V1, P419
[8]  
Lamonte RR, 2001, ADV MATER PROCESS, V159, P33
[9]  
LICARI J, 1990, HDB POLYM COATING EL, P1
[10]   Point-of-need diagnosis of cystic fibrosis using a potentiometric ion-selective electrode array [J].
Lynch, A ;
Diamond, D ;
Leader, M .
ANALYST, 2000, 125 (12) :2264-2267