Feasibility, criterion validity and retest reliability of exercise testing using the Astrand-Rhyming test protocol with an adaptive ergometer in stroke patients

被引:27
作者
Lennon, Olive C. [1 ,2 ,3 ]
Denis, Romain S. [4 ]
Grace, Nuala [2 ]
Blake, Catherine [2 ]
机构
[1] Royal Coll Surgeons Ireland, Sch Physiotherapy, Dublin 2, Ireland
[2] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Populat Sci, Dublin 4, Ireland
[3] Baggot St Community Hosp, Stroke Rehabil Unit, Hlth Serv, Dublin 4, Ireland
[4] Univ Coll Dublin, Inst Sport & Hlth, Dublin 4, Ireland
关键词
cerebrovascular disorders; Astrand-Rhyming protocol; stroke; exercise; BY-BREATH MEASUREMENT; AEROBIC EXERCISE; MAXIMAL EXERCISE; CARDIORESPIRATORY FITNESS; CARDIOVASCULAR FITNESS; CARDIAC REHABILITATION; SUBMAXIMAL EXERCISE; CLINICAL CARDIOLOGY; PHYSICAL-ACTIVITY; RISK REDUCTION;
D O I
10.3109/09638288.2011.635748
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
Purpose: (i) to establish feasibility of the Astrand-Rhyming submaximal protocol using the adaptive ergometer in healthy participants, (ii) to test feasibility of this protocol in stroke patients, (iii) to identify clinical characteristics of stroke patients which limit testing, (iv) to establish criterion validity of VO2 steady state ergometry data against the gold standard open-circuit spirometry measure and, lastly, (v) to test-retest reliability of the data generated by the test protocol. Methods: A descriptive, cross sectional study design was implemented. Ten healthy participants (5 men, mean age 32 +/- 6.6y) and 20 chronic stroke patients (14 men, mean age 61.0 +/- 11.6 y; mean months since stroke, 65.6 +/- 34.4 y) took part in this study. Independent t-tests, Mann Whitney U tests and chi-square test identified characteristics of those who failed to successfully complete the protocol. Interclass correlation coefficients (ICCs) tested criterion validity and test-retest reliability. Results: No adverse events occurred. All healthy participants (100%) complied with the test protocol and estimation of VO2max. 90% of stroke patients completed the test, with VO2max estimated in 35% (7/20) stroke patients. Age and beta-blocker medication demonstrated statistical significance as barriers to the test protocol at p=0.04 and p=0.03, respectively. Criterion validity established by comparison with breath-by-breath gas analysis was excellent (ICC 0.93). Retest reliability of VO2max, steady-state VO2 and oxygen pulse had ICCs of 0.94, 0.96 and 0.97, respectively. Conclusions: The Astrand-Rhyming test protocol and MOTOmed Viva2 adaptive ergometer were feasible in healthy participants. The protocol was not feasible for VO2max estimation for the majority of stroke patients based on heart rate response. The adapted steady state VO2 measures used however were feasible and had strong relationship to actual VO2 consumption. Criterion validity and retest reliability of test data were excellent.
引用
收藏
页码:1149 / 1156
页数:8
相关论文
共 49 条
[1]
[Anonymous], 2005, NORMAL VALUES
[2]
[Anonymous], 2000, ACSMS GUIDELINES EXE
[3]
[Anonymous], 1989, J CARDIOPULM REHABIL
[4]
ASTRAND I, 1960, Acta Physiol Scand Suppl, V49, P1
[5]
Astrand PO., 1986, TXB WORK PHYSL
[6]
THE CARDIOVASCULAR FITNESS OF DISABLED PATIENTS ATTENDING OCCUPATIONAL-THERAPY [J].
BACHYNSKICOLE, M ;
CUMMING, GR .
OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1985, 5 (04) :233-242
[7]
Outcomes validity and reliability of the modified Rankin scale: Implications for stroke clinical trials - A literature review and synthesis [J].
Banks, Jamie L. ;
Marotta, Charles A. .
STROKE, 2007, 38 (03) :1091-1096
[8]
Limiting factors for maximum oxygen uptake and determinants of endurance performance [J].
Bassett, DR ;
Howley, ET .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (01) :70-84
[9]
BREATH-BY-BREATH MEASUREMENT OF TRUE ALVEOLAR GAS-EXCHANGE [J].
BEAVER, WL ;
LAMARRA, N ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (06) :1662-1675
[10]
Modified Total-Body Recumbent Stepper Exercise Test for Assessing Peak Oxygen Consumption in People With Chronic Stroke [J].
Billinger, Sandra A. ;
Tseng, Benjamin Y. ;
Kluding, Patricia M. .
PHYSICAL THERAPY, 2008, 88 (10) :1188-1195