Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma

被引:117
作者
Cates, C. J. [1 ]
Crilly, J. A. [1 ]
Rowe, B. H. [1 ]
机构
[1] Bushey Hlth Ctr, Watford WD23 2NN, Herts, England
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2006年 / 02期
关键词
D O I
10.1002/14651858.CD000052.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In acute asthma inhaled beta 2-agonists are often administered to relieve bronchospasm by wet nebulisation, but some have argued that metered-dose inhalers with a holding chamber (spacer) can be equally effective. Nebulisers require a power source and need regular maintenance, and are more expensive in the community setting. Objectives To assess the effects of holding chambers (spacers) compared to nebulisers for the delivery of beta 2-agonists for acute asthma. Search strategy We last searched the Cochrane Airways Group trials register in January 2006 and the Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 4, 2005). Selection criteria Randomised trials in adults and children (from two years of age) with asthma, where spacer beta 2-agonist delivery was compared with wet nebulisation. Data collection and analysis Two reviewers independently applied study inclusion criteria (one reviewer for the first version of the review), extracted the data and assessed trial quality. Missing data were obtained from the authors or estimated. Results are reported with 95% confidence intervals (CI). Main results This review has been updated in January 2006 and four new trials have been added. 2066 children and 614 adults are now included in 25 trials from emergency room and community settings. In addition, six trials on in-patients with acute asthma (213 children and 28 adults) have been reviewed. Method of delivery of beta 2-agonist did not appear to affect hospital admission rates. In adults, the relative risk of admission for spacer versus nebuliser was 0.97 (95% CI 0.63 to 1.49). The relative risk for children was 0.65 (95% CI: 0.4 to 1.06). In children, length of stay in the emergency department was significantly shorter when the spacer was used, with a mean difference of -0.47 hours (95% CI: -0.58 to -0.37). Length of stay in the emergency department for adults was similar for the two delivery methods. Peak flow and forced expiratory volume were also similar for the two delivery methods. Pulse rate was lower for spacer in children, mean difference -7.6% baseline (95% CI: -9.9 to -5.3% baseline). Authors' conclusions Metered-dose inhalers with spacer produced outcomes that were at least equivalent to nebuliser delivery. Spacers may have some advantages compared to nebulisers for children with acute asthma.
引用
收藏
页数:70
相关论文
共 71 条
[1]   WET NEBULIZER VERSUS SPACER AND METERED DOSE INHALER VIA TIDAL BREATHING [J].
BA, M ;
SPIER, S ;
LAPIERRE, G ;
LAMARRE, A .
JOURNAL OF ASTHMA, 1989, 26 (06) :355-358
[2]  
Batra V, 1997, Indian Pediatr, V34, P497
[3]  
BEASLEY CRW, 1985, NEW ZEAL MED J, V98, P854
[4]  
Benton G, 1989, ANN DIS CHILDHOOD, V43, P678
[5]   COMPARISON OF METERED-DOSE INHALER ATTACHED TO AN AEROCHAMBER WITH AN UPDRAFT NEBULIZER FOR THE ADMINISTRATION OF METAPROTERENOL IN HOSPITALIZED-PATIENTS [J].
BERENBERG, MJ ;
BAIGELMAN, W ;
CUPPLES, LA ;
PEARCE, L .
JOURNAL OF ASTHMA, 1985, 22 (02) :87-92
[6]   RELATIVE AMOUNT OF ALBUTEROL DELIVERED TO LUNG RECEPTORS FROM A METERED-DOSE INHALER AND NEBULIZER SOLUTION - BIOASSAY BY HISTAMINE BRONCHOPROVOCATION [J].
BLAKE, KV ;
HOPPE, M ;
HARMAN, E ;
HENDELES, L .
CHEST, 1992, 101 (02) :309-315
[7]  
*BTS, 2003, THORAX S, V58
[8]  
Burrows T, 2004, THORAX, V59, P20
[9]   AN OPEN, PROSPECTIVE COMPARISON OF BETA(2) AGONISTS GIVEN VIA NEBULIZER, NEBUHALER, OR PRESSURIZED INHALER BY AMBULANCE CREW AS EMERGENCY TREATMENT [J].
CAMPBELL, IA ;
COLMAN, SB ;
MAO, JH ;
PRESCOTT, RJ ;
WESTON, CFM .
THORAX, 1995, 50 (01) :79-80
[10]  
CHONGNETO JHJ, 2005, J PEDIAT J PEDIAT, V81, P298